Development of ultrasonography assistance robot for prenatal care

R. Tsumura, H. Iwata
{"title":"Development of ultrasonography assistance robot for prenatal care","authors":"R. Tsumura, H. Iwata","doi":"10.1117/12.2550038","DOIUrl":null,"url":null,"abstract":"Recently, in the United States as well as other countries, a shortage of obstetrician and gynecologist (ob-gyns) has grown seriously. The obstetrics and gynecology have a high burnout rate compared to other medical specialties because of increased workloads and competing for administrative demands. Then, there is a demand for assisting the procedure of prenatal care, especially ultrasonography. Although several robotic-assisted ultrasound imaging platforms have been developed, there were few platforms focusing on prenatal care. In this paper, we proposed an ultrasonography assistance robot for prenatal care to improve the workload of obstetricians and gynecologists. In prenatal care, it is crucially important to satisfy the safety for the pregnant women and fetus compared to other regions of ultrasonography. This paper serves as the proof of concept of the ultrasonography assistance robot for prenatal care by demonstrating the scan of uterus and estimating amniotic fluid volume for assessing fetus health with the fetal US imaging phantom, and clinical feasibility to one pregnant woman. As the key technology to satisfy the safety and acquired image quality, the mechanism with constant springs that the US probe can be shifted flexibly depending on the abdominal height was proposed. The proposed robot system enabled to scan the entire uterus area keeping the contact force under the force applied in clinical procedures (about 15 N) to the fetus phantom. Additionally, as the first application for evaluating fetus health automatically, the system to estimate the amniotic fluid volume (AFV) based on the acquired US images with the robot system was developed and evaluated with the fetus phantom. The result shows estimation errors within 10%. Finally, we demonstrated the robotic US scan to one pregnant woman and successfully observed the body parts of fetus.","PeriodicalId":302939,"journal":{"name":"Medical Imaging: Image-Guided Procedures","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Imaging: Image-Guided Procedures","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2550038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Recently, in the United States as well as other countries, a shortage of obstetrician and gynecologist (ob-gyns) has grown seriously. The obstetrics and gynecology have a high burnout rate compared to other medical specialties because of increased workloads and competing for administrative demands. Then, there is a demand for assisting the procedure of prenatal care, especially ultrasonography. Although several robotic-assisted ultrasound imaging platforms have been developed, there were few platforms focusing on prenatal care. In this paper, we proposed an ultrasonography assistance robot for prenatal care to improve the workload of obstetricians and gynecologists. In prenatal care, it is crucially important to satisfy the safety for the pregnant women and fetus compared to other regions of ultrasonography. This paper serves as the proof of concept of the ultrasonography assistance robot for prenatal care by demonstrating the scan of uterus and estimating amniotic fluid volume for assessing fetus health with the fetal US imaging phantom, and clinical feasibility to one pregnant woman. As the key technology to satisfy the safety and acquired image quality, the mechanism with constant springs that the US probe can be shifted flexibly depending on the abdominal height was proposed. The proposed robot system enabled to scan the entire uterus area keeping the contact force under the force applied in clinical procedures (about 15 N) to the fetus phantom. Additionally, as the first application for evaluating fetus health automatically, the system to estimate the amniotic fluid volume (AFV) based on the acquired US images with the robot system was developed and evaluated with the fetus phantom. The result shows estimation errors within 10%. Finally, we demonstrated the robotic US scan to one pregnant woman and successfully observed the body parts of fetus.
产前超声辅助机器人的研制
最近,在美国和其他国家,妇产科医生(ob-gyns)的短缺已经严重增长。与其他医学专业相比,由于工作量增加和行政管理需求的竞争,妇产科的倦怠率很高。然后,有一个需求,协助产前护理程序,特别是超声检查。虽然已经开发了几个机器人辅助超声成像平台,但很少有平台专注于产前护理。在本文中,我们提出了超声辅助机器人产前护理,以改善妇产科医生的工作量。在产前护理中,与其他领域的超声检查相比,确保孕妇和胎儿的安全至关重要。本文通过对一名孕妇进行超声辅助机器人产前护理的概念验证,通过胎儿超声成像幻影对子宫进行扫描,估算羊水容量,评估胎儿健康状况,以及临床可行性。作为满足安全性和获得的图像质量的关键技术,提出了一种可随腹部高度灵活移动的恒弹簧机构。所提出的机器人系统能够扫描整个子宫区域,使接触力在临床手术中施加给胎儿的力(约15 N)下。此外,作为首个用于胎儿健康自动评估的应用,利用机器人系统开发了基于获取的US图像估计羊水体积(AFV)的系统,并利用胎儿幻影进行了评估。结果表明,估计误差在10%以内。最后,我们向一位孕妇演示了机器人超声扫描,成功地观察到了胎儿的身体部位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信