Mu-beta rhythm ERD/ERS quantification for foot motor execution and imagery tasks in BCI applications

M. Tariq, L. Uhlenberg, P. Trivailo, K. Munir, M. Simic
{"title":"Mu-beta rhythm ERD/ERS quantification for foot motor execution and imagery tasks in BCI applications","authors":"M. Tariq, L. Uhlenberg, P. Trivailo, K. Munir, M. Simic","doi":"10.1109/COGINFOCOM.2017.8268222","DOIUrl":null,"url":null,"abstract":"Viable usage of Brain-Computer Interface (BCI) in real-time applications significantly relies on the pre-processing techniques applied on the detected electroencephalography (EEG) signals. In EEG, sensorimotor (SMR)/oscillatory signals, such as mu and beta rhythm based BCIs, can be used to restore motor function by neuro-plasticity applied to re-establish normal brain function. This study is based on the evaluation of the foot motor execution (ME) and motor imagery (MI), in order to design a BCI neurorehabilitation system. Because foot ME and MI reflect the user's physical and imagination state of foot movement respectively, in order to be used as control signals, their appropriate translation is the basic challenge. This paper mainly focuses on the quantification and investigation of mu-beta event-related desynchronization (ERD) and event-related synchronization (ERS), for inter and intra-subject variability, making use of the available design tools in open-source platforms such as the OpenViBE software. Results show that the frequency of the most reactive components for mu was 8.8±0.5 Hz and 21.3±0.4 Hz for beta. Interestingly a contralateral dominance was visible at electrode position C3 during right foot ME/MI tasks. The results have enabled the implementation of a good platform for left-right foot ME/MI discrimination based BCI applications.","PeriodicalId":212559,"journal":{"name":"2017 8th IEEE International Conference on Cognitive Infocommunications (CogInfoCom)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 8th IEEE International Conference on Cognitive Infocommunications (CogInfoCom)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/COGINFOCOM.2017.8268222","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

Viable usage of Brain-Computer Interface (BCI) in real-time applications significantly relies on the pre-processing techniques applied on the detected electroencephalography (EEG) signals. In EEG, sensorimotor (SMR)/oscillatory signals, such as mu and beta rhythm based BCIs, can be used to restore motor function by neuro-plasticity applied to re-establish normal brain function. This study is based on the evaluation of the foot motor execution (ME) and motor imagery (MI), in order to design a BCI neurorehabilitation system. Because foot ME and MI reflect the user's physical and imagination state of foot movement respectively, in order to be used as control signals, their appropriate translation is the basic challenge. This paper mainly focuses on the quantification and investigation of mu-beta event-related desynchronization (ERD) and event-related synchronization (ERS), for inter and intra-subject variability, making use of the available design tools in open-source platforms such as the OpenViBE software. Results show that the frequency of the most reactive components for mu was 8.8±0.5 Hz and 21.3±0.4 Hz for beta. Interestingly a contralateral dominance was visible at electrode position C3 during right foot ME/MI tasks. The results have enabled the implementation of a good platform for left-right foot ME/MI discrimination based BCI applications.
脑机接口应用中足部运动执行和图像任务的mu - β节律ERD/ERS量化
脑机接口(BCI)在实时应用中的可行性很大程度上取决于对检测到的脑电图(EEG)信号所采用的预处理技术。在脑电图中,感觉运动(SMR)/振荡信号,如基于mu和β节律的脑机接口,可以通过应用神经可塑性来重建正常的脑功能来恢复运动功能。本研究基于足部运动执行(ME)和运动想象(MI)的评估,设计脑机接口神经康复系统。由于足部ME和MI分别反映了用户足部运动的身体状态和想象状态,因此要想作为控制信号,对它们进行适当的翻译是基本的挑战。本文主要利用开放源代码平台(如OpenViBE软件)中可用的设计工具,对mu-beta事件相关去同步(ERD)和事件相关同步(ERS)进行量化和调查,以实现主体间和主体内的可变性。结果表明,mu和beta的反应频率分别为8.8±0.5 Hz和21.3±0.4 Hz。有趣的是,在右脚ME/MI任务中,C3电极位置可见对侧优势。研究结果为基于脑机接口(BCI)的左右足ME/MI识别应用提供了一个良好的平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信