COMPARISON OF ELECTROCOAGULATION COUPLED WITH SYNTHETIC ZEOLITE, ULTRASOUND AND TWO STEPS ELECTROCOAGULATION

N. Vukojević Medvidović, L. Vrsalović, Sandra Svilović, Mirjana Cestarić
{"title":"COMPARISON OF ELECTROCOAGULATION COUPLED WITH SYNTHETIC ZEOLITE,\nULTRASOUND AND TWO STEPS ELECTROCOAGULATION","authors":"N. Vukojević Medvidović, L. Vrsalović, Sandra Svilović, Mirjana Cestarić","doi":"10.57131/jstm.2022.3.1","DOIUrl":null,"url":null,"abstract":"Due to the very complex composition of leachate wastewater, combining two or more physical, chemical,\nor biological processes, carried out simultaneously or sequentially, is highly needed in order to obtain\neffluent suitable for further discharge into sewage. In this paper, electrocoagulation coupled with\nsynthetic zeolite (EC-NaX), electrocoagulation coupled with ultrasound (EC-US), and two steps\nelectrocoagulation (EC-1st and EC-2nd) were tested for compost leachate treatment, with very high initial\norganic loading and acidic pH. The comparison of each process was done in regard to the following\nparameters: pH, electrical conductivity and temperature change, removal percentage of chemical oxygen\ndemand (COD), turbidity, total solids change, settling ability, and electrode consumption. Results highlight\nthe EC-NaX as the best option for the treatment of compost leachate, due to the highest removal\npercentage of COD (51.91%), satisfactory removal percentage of turbidity (97%), good settling abilities, and\nlowest electrode consumption. However, the final COD values in the effluent are still significantly high\nfor further discharge into sewage systems, thus additional treatment needs to be applied. Also, the final\nacidic pH, high values of electrical conductivity, and high temperature of effluent need to be solved in\nfurther treatment steps.","PeriodicalId":349778,"journal":{"name":"VOL. 2, NO. 3 (2022)","volume":"41 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"VOL. 2, NO. 3 (2022)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.57131/jstm.2022.3.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Due to the very complex composition of leachate wastewater, combining two or more physical, chemical, or biological processes, carried out simultaneously or sequentially, is highly needed in order to obtain effluent suitable for further discharge into sewage. In this paper, electrocoagulation coupled with synthetic zeolite (EC-NaX), electrocoagulation coupled with ultrasound (EC-US), and two steps electrocoagulation (EC-1st and EC-2nd) were tested for compost leachate treatment, with very high initial organic loading and acidic pH. The comparison of each process was done in regard to the following parameters: pH, electrical conductivity and temperature change, removal percentage of chemical oxygen demand (COD), turbidity, total solids change, settling ability, and electrode consumption. Results highlight the EC-NaX as the best option for the treatment of compost leachate, due to the highest removal percentage of COD (51.91%), satisfactory removal percentage of turbidity (97%), good settling abilities, and lowest electrode consumption. However, the final COD values in the effluent are still significantly high for further discharge into sewage systems, thus additional treatment needs to be applied. Also, the final acidic pH, high values of electrical conductivity, and high temperature of effluent need to be solved in further treatment steps.
电混凝与合成沸石、超声和两步电混凝的比较
由于渗滤液废水的成分非常复杂,因此迫切需要同时或依次进行两种或两种以上的物理、化学或生物过程,以获得适合进一步排放到污水中的流出物。本文采用电混凝-合成沸石(EC-NaX)、电混凝-超声(EC-US)和两步选择电混凝(ec -1和ec -2)处理堆肥渗滤液,具有很高的初始有机负荷和酸性ph。各工艺在以下参数方面进行了比较:pH、电导率和温度变化、化学需氧量(COD)去除率、浊度、总固体变化、沉降能力和电极消耗。结果表明,EC-NaX是处理堆肥渗滤液的最佳选择,其COD去除率最高(51.91%),浊度去除率满意(97%),沉降能力好,电极消耗最低。然而,废水中的最终COD值仍然很高,无法进一步排放到污水系统中,因此需要进行额外的处理。此外,最终的酸性pH值、高电导率值和出水高温需要在进一步的处理步骤中解决。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信