{"title":"Power Quality at the Input of DC Motor and Controlled Rectifier Driving Systems","authors":"A. Bitoleanu, M. Popescu, M. Dobriceanu","doi":"10.1109/EPEPEMC.2006.4778590","DOIUrl":null,"url":null,"abstract":"This paper focuses on the harmonic at the network of the driving systems with DC motors and controlled rectifier. Notably, the total harmonic distortion factor (THD) is influenced by the rectifier commutation and by the load current filtering. We found these influences (thyristors commutation and filtering inductivity) concerning the waves of the currents in the secondary of the transformer and in the network and the waves of the voltage in the secondary of the transformer, as well as the correspondent harmonics spectra. The achieved MATLAB-STMULINK model corresponds to a driving system supplied from a three-phase controlled rectifier. The numerical results are accompanied by experimental verifications, which validate the Simulink models and we done a comparison by IEC 1000-2-1 relation. The active harmonics filtering in dynamic state is discussed.","PeriodicalId":401288,"journal":{"name":"2006 12th International Power Electronics and Motion Control Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 12th International Power Electronics and Motion Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEPEMC.2006.4778590","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
This paper focuses on the harmonic at the network of the driving systems with DC motors and controlled rectifier. Notably, the total harmonic distortion factor (THD) is influenced by the rectifier commutation and by the load current filtering. We found these influences (thyristors commutation and filtering inductivity) concerning the waves of the currents in the secondary of the transformer and in the network and the waves of the voltage in the secondary of the transformer, as well as the correspondent harmonics spectra. The achieved MATLAB-STMULINK model corresponds to a driving system supplied from a three-phase controlled rectifier. The numerical results are accompanied by experimental verifications, which validate the Simulink models and we done a comparison by IEC 1000-2-1 relation. The active harmonics filtering in dynamic state is discussed.