Battery Tripping Unit for Space Constrained Substation Container Applications

Johan Venter, D. van Niekerk
{"title":"Battery Tripping Unit for Space Constrained Substation Container Applications","authors":"Johan Venter, D. van Niekerk","doi":"10.1109/SAUPEC/RobMech/PRASA52254.2021.9377212","DOIUrl":null,"url":null,"abstract":"Protecting power and distribution equipment from major faults will aid in preventing infrastructure damage and unnecessary power supply losses. Battery operated tripping units are used to open (trip) or re-close HT breakers in a substation during power supply failures. Short bursts of high currents from a battery bank in the substation switch room is used to energize open and close coils of HT breakers. A proposed 30 V, 10 A charger with an adequate battery bank can be an ideal sized unit for HT breaker tripping applications in a space constrained substation container (750 mm x570 mm x280 mm), placed in remote areas. To ensure easy unit access and serviceability, the batteries, control system and battery charger power module are all integrated into a single enclosed mountable cabinet unit. The dimensions and mass of the proposed housing cabinet was minimized to optimize space utilization and easy mobility. The housing cabinet can then be wall mounted or even placed on the floor, allowing it to be easily moved in the substation from one location to another. The PC board is also conformal coated to protect against corrosion due to humidity and a properly designed solder mask avoids unintentional short circuits. The battery charger makes use of a thyristor controlled full-wave bridge rectifier to charge the battery bank and will also include appropriate diagnostic faultfinding warning alarms. The proposed 30 V, 10 A battery charger system addresses some shortcomings of current battery charger implementations at remote substations, especially when the system is required to operate at higher ambient temperatures. This proposed battery charger system makes it possible to use up to 25 nickel cadmium cells or 15 lead acid cells to continuously supply 30 V at 10 A for fast charging and/or standing loads or both. In addition, several features have been added to assist technicians in determining potential battery charger faults in order to reduce breakdown times.","PeriodicalId":442944,"journal":{"name":"2021 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SAUPEC/RobMech/PRASA52254.2021.9377212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Protecting power and distribution equipment from major faults will aid in preventing infrastructure damage and unnecessary power supply losses. Battery operated tripping units are used to open (trip) or re-close HT breakers in a substation during power supply failures. Short bursts of high currents from a battery bank in the substation switch room is used to energize open and close coils of HT breakers. A proposed 30 V, 10 A charger with an adequate battery bank can be an ideal sized unit for HT breaker tripping applications in a space constrained substation container (750 mm x570 mm x280 mm), placed in remote areas. To ensure easy unit access and serviceability, the batteries, control system and battery charger power module are all integrated into a single enclosed mountable cabinet unit. The dimensions and mass of the proposed housing cabinet was minimized to optimize space utilization and easy mobility. The housing cabinet can then be wall mounted or even placed on the floor, allowing it to be easily moved in the substation from one location to another. The PC board is also conformal coated to protect against corrosion due to humidity and a properly designed solder mask avoids unintentional short circuits. The battery charger makes use of a thyristor controlled full-wave bridge rectifier to charge the battery bank and will also include appropriate diagnostic faultfinding warning alarms. The proposed 30 V, 10 A battery charger system addresses some shortcomings of current battery charger implementations at remote substations, especially when the system is required to operate at higher ambient temperatures. This proposed battery charger system makes it possible to use up to 25 nickel cadmium cells or 15 lead acid cells to continuously supply 30 V at 10 A for fast charging and/or standing loads or both. In addition, several features have been added to assist technicians in determining potential battery charger faults in order to reduce breakdown times.
用于空间受限变电站集装箱的电池脱扣装置
保护电力和配电设备免受重大故障的影响将有助于防止基础设施损坏和不必要的供电损失。电池操作的脱扣装置用于在电源故障期间打开(脱扣)或重新关闭变电站的高温断路器。从变电站开关室的蓄电池组中产生的大电流的短脉冲用来激励高压断路器的开合线圈。建议的30v, 10a充电器和足够的电池组可以是一个理想的尺寸单元,用于在空间有限的变电站容器(750毫米x570毫米x280毫米)中HT断路器跳闸应用,放置在偏远地区。为了保证设备的易用性和可维护性,电池、控制系统和电池充电器电源模块都集成在一个封闭的可挂装机柜单元中。拟议的住房柜的尺寸和质量被最小化,以优化空间利用和方便移动。然后,外壳柜可以安装在墙上,甚至可以放置在地板上,使其能够轻松地在变电站中从一个位置移动到另一个位置。PC板也是保形涂层,以防止腐蚀由于湿度和一个适当设计的阻焊避免无意的短路。电池充电器使用可控硅控制的全波桥式整流器对电池组充电,还将包括适当的诊断故障查找警告警报。提出的30v, 10a电池充电系统解决了目前远程变电站电池充电实现的一些缺点,特别是当系统需要在较高的环境温度下运行时。这种提出的电池充电器系统可以使用多达25个镍镉电池或15个铅酸电池,以10 A的电压连续供应30 V,用于快速充电和/或固定负载或两者兼而有之。此外,还增加了几个功能,以帮助技术人员确定潜在的电池充电器故障,以减少故障时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信