{"title":"Unbiased two-stage bilateral and non-local approach for MRI denoising","authors":"G. K. Punj","doi":"10.1109/CCINTELS.2016.7878201","DOIUrl":null,"url":null,"abstract":"Denoising of MR (Magnetic Resonance) images is one of the crucial tasks in the field of medicine as it is often corrupted by Rician noise which exhibits a signal dependent behaviour at different SNR. Due to the biased nature of Rician noise, it is a challenging task to attenuate Rician noise from MR images. In this paper, we analyse the basic and effective MRI denoising techniques. Also, we have proposed a two-stage denoising procedure which has a strong potential to remove Rician noise from MR images effectively. The efficacy of proposed two-stage MRI denoising method is analysed through qualitative and quantitative measures and it is observed that the performance of the proposed two-stage denoising procedure is superior to single-stage MRI denoising methods.","PeriodicalId":158982,"journal":{"name":"2016 2nd International Conference on Communication Control and Intelligent Systems (CCIS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 2nd International Conference on Communication Control and Intelligent Systems (CCIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCINTELS.2016.7878201","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Denoising of MR (Magnetic Resonance) images is one of the crucial tasks in the field of medicine as it is often corrupted by Rician noise which exhibits a signal dependent behaviour at different SNR. Due to the biased nature of Rician noise, it is a challenging task to attenuate Rician noise from MR images. In this paper, we analyse the basic and effective MRI denoising techniques. Also, we have proposed a two-stage denoising procedure which has a strong potential to remove Rician noise from MR images effectively. The efficacy of proposed two-stage MRI denoising method is analysed through qualitative and quantitative measures and it is observed that the performance of the proposed two-stage denoising procedure is superior to single-stage MRI denoising methods.