{"title":"Power losses evaluation of two and three-level NPC inverters considering drive applications","authors":"L. Cloţea, A. Forcos","doi":"10.1109/OPTIM.2012.6231984","DOIUrl":null,"url":null,"abstract":"Wind pumped storage systems are becoming more and more attractive in the context of higher quantities of wind power to be absorbed by the grid, power system stability, load balancing and frequency control. The power losses of a pump drive inverter system are evaluated considering two different topologies: 2L VSC and respectively 3L NPC VSC starting from 2.2 kW up to 1.85 MW power levels. The analyze is based on practical application considering the standard LV and MV of the induction machine supply RMS voltages and the latest IGBT 3, IGBT 4 (trench technology) and the press-pack IGBT technology for the semiconductor switches.","PeriodicalId":382406,"journal":{"name":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","volume":"30 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 13th International Conference on Optimization of Electrical and Electronic Equipment (OPTIM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/OPTIM.2012.6231984","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Wind pumped storage systems are becoming more and more attractive in the context of higher quantities of wind power to be absorbed by the grid, power system stability, load balancing and frequency control. The power losses of a pump drive inverter system are evaluated considering two different topologies: 2L VSC and respectively 3L NPC VSC starting from 2.2 kW up to 1.85 MW power levels. The analyze is based on practical application considering the standard LV and MV of the induction machine supply RMS voltages and the latest IGBT 3, IGBT 4 (trench technology) and the press-pack IGBT technology for the semiconductor switches.
考虑驱动应用的二电平和三电平NPC逆变器的功率损耗评估
在风电被电网大量吸收、电力系统稳定、负载平衡和频率控制的背景下,风力抽水蓄能系统变得越来越有吸引力。考虑两种不同的拓扑,分别为2L VSC和3L NPC VSC,从2.2 kW到1.85 MW的功率水平,对泵驱动逆变器系统的功率损耗进行了评估。分析基于实际应用,考虑了感应电机的标准低压和中压电源有效值电压以及半导体开关的最新IGBT 3, IGBT 4(沟槽技术)和压包IGBT技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信