{"title":"Removal Amount Difference between Anode and Cathode in EDM Process","authors":"Heng Xia, M. Kunieda, N. Nishiwaki","doi":"10.2526/JSEME.28.59_31","DOIUrl":null,"url":null,"abstract":"The pulse duration of discharge current greatly influences the removal amount of anode and cathode in EDM process. The purpose of this research is to find out the reason for such a phenomenon. At first, the energy distributed into anode and cathode in the case of the single discharge process is obtained by means of measuring the temperature rise and removal amount of electrodes. Then the influence of the carbon adhesion onto the anode surface on the anode removal amount is investigated. It is found that the energy distributed into the anode is more than that into the cathode, and the influence of pulse duration on the energy distribution is small. Besides, it is concluded from the experimental results that the removal amount difference between anode and cathode in the EDM process is mainly caused by carbon adhesion, not by the energy distribution.","PeriodicalId":407646,"journal":{"name":"International Journal of Electrical Machining","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"147","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical Machining","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2526/JSEME.28.59_31","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 147

Abstract

The pulse duration of discharge current greatly influences the removal amount of anode and cathode in EDM process. The purpose of this research is to find out the reason for such a phenomenon. At first, the energy distributed into anode and cathode in the case of the single discharge process is obtained by means of measuring the temperature rise and removal amount of electrodes. Then the influence of the carbon adhesion onto the anode surface on the anode removal amount is investigated. It is found that the energy distributed into the anode is more than that into the cathode, and the influence of pulse duration on the energy distribution is small. Besides, it is concluded from the experimental results that the removal amount difference between anode and cathode in the EDM process is mainly caused by carbon adhesion, not by the energy distribution.
电火花加工中正极去除率的差异
放电电流的脉冲持续时间对电火花加工过程中阳极和阴极的去除率有很大影响。本研究的目的是找出造成这种现象的原因。首先,通过测量电极的温升和去除量,得到单次放电过程中分布在阳极和阴极上的能量。然后研究了碳在阳极表面的附着对阳极去除率的影响。研究发现,进入阳极的能量大于进入阴极的能量,脉冲持续时间对能量分布的影响较小。此外,从实验结果可以看出,在电火花加工过程中,阳极和阴极的去除率差异主要是由碳附着引起的,而不是由能量分布引起的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信