The quality of Haemoglobin examination results with variations in incubation time using the Cyanmethemoglobin method

Ellies Tunjung, Fitrotin Azizah, V. Rohmayani, Baterun Kunsah, Rizka Vera Yunia
{"title":"The quality of Haemoglobin examination results with variations in incubation time using the Cyanmethemoglobin method","authors":"Ellies Tunjung, Fitrotin Azizah, V. Rohmayani, Baterun Kunsah, Rizka Vera Yunia","doi":"10.21580/jnsmr.2020.6.2.11224","DOIUrl":null,"url":null,"abstract":"Anaemia is a condition where blood red blood levels or haemoglobin is lower than normal values. More than 50% of cases of anaemia are spread throughout the world. One of checks to diagnose anaemia is examination of haemoglobin levels. Examination of haemoglobin levels can be determined by several methods, namely the Sahli’s method, the Cyanmethemoglobin method manually and by automatic method. Examination of haemoglobin levels with a of more than 5 minutes incubation time leads to inaccurate results. The purpose of this research is to determine the effect of incubation time on the results of haemoglobin level examination of the Cyanmethemoglobin method. This type of research is experimental research to determine the effect of the incubation time on the results of haemoglobin level examination of the Cyanmethemoglobin method. The population in this research is outpatients with a diagnosis of kidney failure at Gatoel Hospital, Mojokerto, in March 2019. The number of examination samples is 9 samples which is carried out at the Gatoel Hospital Laboratory, Mojokerto. The results of this research show that the average haemoglobin incubation rate of 5 minutes is 7,52 g/dl, incubation of 20 minutes is 7,18 g / dl, and incubation of 30 minutes is 7,04 g / dl. The conclusion of this research is that there is no effect on the delay in incubation time on the results of the haemoglobin level examination of the Cyanmethemoglobin method.","PeriodicalId":191192,"journal":{"name":"Journal of Natural Sciences and Mathematics Research","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Natural Sciences and Mathematics Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21580/jnsmr.2020.6.2.11224","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Anaemia is a condition where blood red blood levels or haemoglobin is lower than normal values. More than 50% of cases of anaemia are spread throughout the world. One of checks to diagnose anaemia is examination of haemoglobin levels. Examination of haemoglobin levels can be determined by several methods, namely the Sahli’s method, the Cyanmethemoglobin method manually and by automatic method. Examination of haemoglobin levels with a of more than 5 minutes incubation time leads to inaccurate results. The purpose of this research is to determine the effect of incubation time on the results of haemoglobin level examination of the Cyanmethemoglobin method. This type of research is experimental research to determine the effect of the incubation time on the results of haemoglobin level examination of the Cyanmethemoglobin method. The population in this research is outpatients with a diagnosis of kidney failure at Gatoel Hospital, Mojokerto, in March 2019. The number of examination samples is 9 samples which is carried out at the Gatoel Hospital Laboratory, Mojokerto. The results of this research show that the average haemoglobin incubation rate of 5 minutes is 7,52 g/dl, incubation of 20 minutes is 7,18 g / dl, and incubation of 30 minutes is 7,04 g / dl. The conclusion of this research is that there is no effect on the delay in incubation time on the results of the haemoglobin level examination of the Cyanmethemoglobin method.
用氰高铁血红蛋白法检测血红蛋白的质量随孵育时间的变化
贫血是一种血红蛋白或血红蛋白水平低于正常值的疾病。50%以上的贫血病例分布在世界各地。诊断贫血的检查之一是检查血红蛋白水平。血红蛋白水平的检测可以通过几种方法来确定,即Sahli法、氰高铁血红蛋白法、手动法和自动法。血红蛋白水平的检查超过5分钟的潜伏期导致不准确的结果。本研究的目的是确定培养时间对氰高铁血红蛋白法血红蛋白水平检查结果的影响。这种类型的研究是实验性研究,以确定培养时间对氰高铁血红蛋白法血红蛋白水平检查结果的影响。本研究的人群是2019年3月在Mojokerto Gatoel医院诊断为肾衰竭的门诊患者。检查样本的数量为9个,在Mojokerto的Gatoel医院实验室进行。本研究结果表明,5分钟的平均血红蛋白孵育率为7.52 g/dl, 20分钟的平均血红蛋白孵育率为7.18 g/dl, 30分钟的平均血红蛋白孵育率为7.04 g/dl。本研究的结论是,孵育时间的延迟对氰高铁血红蛋白法的血红蛋白水平检查结果没有影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信