iSCSI and CIFS Network Disks for RAID0/RAID 1 Configurations

M. Simeunović, B. Djordjevic, V. Timčenko, N. Jankovic
{"title":"iSCSI and CIFS Network Disks for RAID0/RAID 1 Configurations","authors":"M. Simeunović, B. Djordjevic, V. Timčenko, N. Jankovic","doi":"10.1109/TELFOR.2018.8611977","DOIUrl":null,"url":null,"abstract":"In this paper, we have tested the impact of the network disk configuration to the system performances. The performance analysis compares two network disk configurations, practically evaluating two different network protocols using identical physical disk configurations. One network drive is configured to operate as an iSCSI block device, while the other operates as a network share disk using CIFS protocol. Testing procedure is based on the use of DiskSpd tool and encompasses measurement of the flow rate, number of the operations and the average response time. Based on the results, iSCSI shows significantly higher flow rates and lower delay values as the size of the data block grows. In smaller blocks, the differences between iSCSI and CIFS are almost negligible.","PeriodicalId":229131,"journal":{"name":"2018 26th Telecommunications Forum (TELFOR)","volume":"53 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 26th Telecommunications Forum (TELFOR)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TELFOR.2018.8611977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper, we have tested the impact of the network disk configuration to the system performances. The performance analysis compares two network disk configurations, practically evaluating two different network protocols using identical physical disk configurations. One network drive is configured to operate as an iSCSI block device, while the other operates as a network share disk using CIFS protocol. Testing procedure is based on the use of DiskSpd tool and encompasses measurement of the flow rate, number of the operations and the average response time. Based on the results, iSCSI shows significantly higher flow rates and lower delay values as the size of the data block grows. In smaller blocks, the differences between iSCSI and CIFS are almost negligible.
用于RAID0/RAID 1配置的iSCSI和CIFS网络盘
在本文中,我们测试了网络磁盘配置对系统性能的影响。性能分析比较了两种网络磁盘配置,实际评估了使用相同物理磁盘配置的两种不同的网络协议。其中一个网络驱动器配置为iSCSI块设备,另一个通过CIFS协议配置为网络共享磁盘。测试过程基于DiskSpd工具的使用,包括流量、操作次数和平均响应时间的测量。根据结果,随着数据块的大小增加,iSCSI显示出明显更高的流量和更低的延迟值。在较小的块中,iSCSI和CIFS之间的差异几乎可以忽略不计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信