A Multi-surgeon Robotic-guided Thoracolumbar Fusion Experience: Accuracy, Radiation, Complications, Readmissions, and Revisions of 3,874 Screws across Three Robotic Generations

IF 0.7
Alexandra E. Thomson, Lindsay D. Orosz, C. Haines, E. Jazini, Fenil R. Bhatt, Julia Grigorian, Andre Sabet, Rita Roy, T. Schuler, Christopher R. Good
{"title":"A Multi-surgeon Robotic-guided Thoracolumbar Fusion Experience: Accuracy, Radiation, Complications, Readmissions, and Revisions of 3,874 Screws across Three Robotic Generations","authors":"Alexandra E. Thomson, Lindsay D. Orosz, C. Haines, E. Jazini, Fenil R. Bhatt, Julia Grigorian, Andre Sabet, Rita Roy, T. Schuler, Christopher R. Good","doi":"10.21182/jmisst.2022.00479","DOIUrl":null,"url":null,"abstract":"Objective: Robotic guidance provides indirect visualization of key anatomic landmarks to facilitate minimally invasive surgery (MIS) and is emerging as a reliable and accurate technique for posterior spine instrumentation. We sought to describe eight years of experience with robotic guidance at a high-volume, multi-surgeon center. We hypothesize that robotic guidance will lead to (1) low rates of complication, readmissions, and revision surgery, (2) reduced fluoroscopic radiation exposure, (3) and accurate thoracolumbar instrumentation. Methods: A retrospective review of complications, revision surgery, and readmission rates in patients undergoing thoracolumbar fusion surgery utilizing three robotic generations. Second-ary analysis was conducted comparing the three robotic generations for complications, revision surgery, accuracy, and readmission rates along with intraoperative fluoroscopic duration. Results: A total of 628 patients (3,874 robotic-guided screws) ages 12–81 years-old (43.9% male) were included in the study. At one year, the cumulative complication incidence was 15.5% with a 10.3% incidence of surgical complications (3.7% wound, 1.2% robot-related, and 5.4% non-robot-related complications). At one year, the revision surgery incidence was 9.4%. There was no statistical difference between complications, readmission, or revision surgery after initial admission among the three robotic generations. The average intraoperative fluoroscopic duration was 53.8 seconds (11.9 seconds per screw and 17.6 seconds per instrumented level). Conclusion: Robotic guidance in thoracolumbar instrumented fusions was associated with low complication, revision surgery, and readmission rates. Our results suggest robotic guidance can provide accurate guidance with minimal adverse events in thoracolumbar instrumentation.","PeriodicalId":405058,"journal":{"name":"Journal of Minimally Invasive Spine Surgery and Technique","volume":"5 1","pages":"0"},"PeriodicalIF":0.7000,"publicationDate":"2022-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Minimally Invasive Spine Surgery and Technique","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21182/jmisst.2022.00479","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Robotic guidance provides indirect visualization of key anatomic landmarks to facilitate minimally invasive surgery (MIS) and is emerging as a reliable and accurate technique for posterior spine instrumentation. We sought to describe eight years of experience with robotic guidance at a high-volume, multi-surgeon center. We hypothesize that robotic guidance will lead to (1) low rates of complication, readmissions, and revision surgery, (2) reduced fluoroscopic radiation exposure, (3) and accurate thoracolumbar instrumentation. Methods: A retrospective review of complications, revision surgery, and readmission rates in patients undergoing thoracolumbar fusion surgery utilizing three robotic generations. Second-ary analysis was conducted comparing the three robotic generations for complications, revision surgery, accuracy, and readmission rates along with intraoperative fluoroscopic duration. Results: A total of 628 patients (3,874 robotic-guided screws) ages 12–81 years-old (43.9% male) were included in the study. At one year, the cumulative complication incidence was 15.5% with a 10.3% incidence of surgical complications (3.7% wound, 1.2% robot-related, and 5.4% non-robot-related complications). At one year, the revision surgery incidence was 9.4%. There was no statistical difference between complications, readmission, or revision surgery after initial admission among the three robotic generations. The average intraoperative fluoroscopic duration was 53.8 seconds (11.9 seconds per screw and 17.6 seconds per instrumented level). Conclusion: Robotic guidance in thoracolumbar instrumented fusions was associated with low complication, revision surgery, and readmission rates. Our results suggest robotic guidance can provide accurate guidance with minimal adverse events in thoracolumbar instrumentation.
多外科医生机器人引导的胸腰椎融合经验:准确性,辐射,并发症,再入院,以及三代机器人3874枚螺钉的修订
目的:机器人引导提供了关键解剖标志的间接可视化,以促进微创手术(MIS),并且正在成为后路脊柱内固定的可靠和准确的技术。我们试图描述在一个大容量、多外科医生中心八年的机器人指导经验。我们假设机器人引导将导致(1)低并发症、再入院和翻修手术的发生率,(2)减少透视辐射暴露,(3)和准确的胸腰椎内固定。方法:回顾性分析采用三代机器人进行胸腰椎融合手术患者的并发症、翻修手术和再入院率。第二次分析比较了三代机器人的并发症、翻修手术、准确性、再入院率以及术中透视时间。结果:共纳入628例患者(3874枚机器人引导螺钉),年龄12-81岁,其中男性43.9%。一年后,累计并发症发生率为15.5%,手术并发症发生率为10.3%(3.7%为伤口,1.2%为机器人相关,5.4%为非机器人相关并发症)。一年时,翻修手术发生率为9.4%。在首次入院后,三代机器人在并发症、再入院或翻修手术方面没有统计学差异。术中平均透视时间为53.8秒(每个螺钉11.9秒,每个固定节段17.6秒)。结论:机器人引导胸腰椎内固定融合术并发症少,翻修手术少,再入院率低。我们的研究结果表明,机器人引导可以在胸腰椎内固定中提供准确的引导,并且不良事件最少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书