Shouta Sora, Kousei Kumahara, M. Eguchi, F. Kuroki, T. Yamakawa, Fumihiro Tanaka
{"title":"Numerical and Experimental Investigations on Ring Resonator Type of Electrode for Circulating Tumor Cell Detection","authors":"Shouta Sora, Kousei Kumahara, M. Eguchi, F. Kuroki, T. Yamakawa, Fumihiro Tanaka","doi":"10.1109/RWS.2019.8714318","DOIUrl":null,"url":null,"abstract":"A ring resonator type of electrode to detect the circulating tumor cell (CTC) has been proposed because the early diagnosis can be performed and the cell condition can be investigated. Main emphasis was placed on the improvement of the Q-factor for high detection sensitivity. The low loss aluminum, Al membrane was deposited on the surface of the dielectric substrate and the thick copper, Cu was plated on the aluminum as the electrode thorough the lossy titanium, Ti as the adhesive. The Q-factor of the ring resonator was calculated to be about 100 at X-band frequencies thanks to the Al – Ti – Cu layered structure. To confirm the capability for the cell detection, the BaTiO3 particles were inserted in the ring resonator type of electrodes instead of CTCs as preliminary experiment. The cell identification could be performed from the numerically and experimentally investigations.","PeriodicalId":131330,"journal":{"name":"2019 IEEE Radio and Wireless Symposium (RWS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Radio and Wireless Symposium (RWS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/RWS.2019.8714318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A ring resonator type of electrode to detect the circulating tumor cell (CTC) has been proposed because the early diagnosis can be performed and the cell condition can be investigated. Main emphasis was placed on the improvement of the Q-factor for high detection sensitivity. The low loss aluminum, Al membrane was deposited on the surface of the dielectric substrate and the thick copper, Cu was plated on the aluminum as the electrode thorough the lossy titanium, Ti as the adhesive. The Q-factor of the ring resonator was calculated to be about 100 at X-band frequencies thanks to the Al – Ti – Cu layered structure. To confirm the capability for the cell detection, the BaTiO3 particles were inserted in the ring resonator type of electrodes instead of CTCs as preliminary experiment. The cell identification could be performed from the numerically and experimentally investigations.
提出了一种环形谐振式电极检测循环肿瘤细胞(CTC),因为它可以进行早期诊断和细胞状况的调查。重点是提高q因子的检测灵敏度。在介质衬底和厚铜表面沉积低损耗铝、铝膜,通过损耗钛在铝表面镀Cu作为电极,Ti作为粘合剂。由于Al - Ti - Cu层状结构,环形谐振器在x波段的q因子约为100。为了验证电池检测的能力,将BaTiO3颗粒插入环形谐振器型电极中,而不是ctc作为初步实验。细胞鉴定可以通过数值和实验研究进行。