{"title":"Penentuan Sisa Umur Pakai Struktur Conveyor F pada Tambang Batubara PT GHI di Kabupaten Tapin, Provinsi Kalimantan Selatan","authors":"Rizqi Saefulfikri, Elfida Moralista, Zaenal","doi":"10.29313/bcsme.v3i2.8638","DOIUrl":null,"url":null,"abstract":"Abstract. In the mining industry, there is a means of transportation for the process of moving mining materials, such as coal, by using a conveyor structure. The structure of the conveyor is made of steel so it is prone to corrosion by reacting with the environment. Corrosion can cause a loss that can result in a reduction in the thickness of the conveyor structure. Therefore, it is necessary to carry out control activities to monitoring in observations on the conveyor structure so that corrosion can be prevented. This study aims to determine the type of corrosion, corrosion rate, remaining service life, and control methods on the conveyor structure. The research methodology used is measuring the thickness reduction of the conveyor structure. The research was conducted on a conveyor structure with a length of 90 meters and 25 test points above ground level. The instrument used in measuring the thickness of the conveyor structure is Ultrasonic Thickness Gauge TT 130. The environmental conditions in the research area are air temperature in the range of 31oC - 37oC, while rainfall is in the range of 6.05 - 11.23 mm/year. The type of corrosion that occurs in this conveyor structure is uniform corrosion. The corrosion control method applied is the coating method with the primary coating using Seaguard 5000, the intermediate coating using Sherglass FF, and the top coating using aliphatic acrylic modified polyurethane. The corrosion rate on this conveyor structure ranges from 0.1828 - 0.3028 mm/year. This value is included in the good category based on the relative corrosion resistance of steel. The residual value of the conveyor structure's service life ranges from 7.19 to 9.65 years. Based on the calculation of the remaining service life of the conveyor structure at 25 test points, there are 24% which are estimated to not be able to reach the design life of 15 years. \nAbstrak. Dalam industri pertambangan terdapat alat transportasi untuk melakukan pemindahan material hasil penambangan yaitu dengan menggunakan struktur conveyor. Struktur conveyor terbuat dari baja yang rawan mengalami korosi dan beraksi dengan lingkungan. Korosi dapat menimbulkan suatu kerugian yang dapat mengakibatkan pengurangan ketebalan pada struktur conveyor. Oleh karena itu, perlu dilakukan kegiatan pengendalian hingga monitoring pada struktur conveyor agar mencegah korosi. Penelitian ini bertujuan untuk mengetahui jenis korosi, laju korosi, sisa umur pakai, dan metoda pengendalian pada struktur conveyor. Metodologi penelitian yang digunakan adalah pengukuran pengurangan ketebalan struktur conveyor. Penelitian dilakukan terhadap struktur conveyor dengan panjang 90 meter dan 25 test point. Alat yang digunakan dalam pengukuran ketebalan struktur conveyor yaitu Ultrasonic Thickness Gauge TT 130. Kondisi lingkungan di daerah penelitian yaitu temperatur udara kisaran 31oC - 37oC, sedangkan curah hujan kisaran 6,05 - 11,23 mm/tahun. Jenis korosi yang terjadi pada struktur conveyor ini yaitu korosi merata. Metode pengendalian korosi yang diaplikasikan adalah metode coating dengan primer coating menggunakan Seaguard 5000, intermediate coating menggunakan Sherglass FF, dan top coating menggunakan aliphatic acrylic modified polyurethane. Laju korosi pada struktur conveyor ini berkisar antara 0,1828 - 0,3028 mm/tahun. Nilai tersebut masuk ke dalam kategori good berdasarkan ketahanan korosi relatif baja. Nilai sisa umur pakai struktur conveyor yaitu 7,19 - 9,65 tahun. Berdasarkan dari perhitungan sisa umur pakai struktur conveyor pada 25 test point, terdapat sebesar 24% yang diperkirakan tidak dapat mencapai umur desain yaitu 15 tahun.","PeriodicalId":187584,"journal":{"name":"Bandung Conference Series: Mining Engineering","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bandung Conference Series: Mining Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29313/bcsme.v3i2.8638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract. In the mining industry, there is a means of transportation for the process of moving mining materials, such as coal, by using a conveyor structure. The structure of the conveyor is made of steel so it is prone to corrosion by reacting with the environment. Corrosion can cause a loss that can result in a reduction in the thickness of the conveyor structure. Therefore, it is necessary to carry out control activities to monitoring in observations on the conveyor structure so that corrosion can be prevented. This study aims to determine the type of corrosion, corrosion rate, remaining service life, and control methods on the conveyor structure. The research methodology used is measuring the thickness reduction of the conveyor structure. The research was conducted on a conveyor structure with a length of 90 meters and 25 test points above ground level. The instrument used in measuring the thickness of the conveyor structure is Ultrasonic Thickness Gauge TT 130. The environmental conditions in the research area are air temperature in the range of 31oC - 37oC, while rainfall is in the range of 6.05 - 11.23 mm/year. The type of corrosion that occurs in this conveyor structure is uniform corrosion. The corrosion control method applied is the coating method with the primary coating using Seaguard 5000, the intermediate coating using Sherglass FF, and the top coating using aliphatic acrylic modified polyurethane. The corrosion rate on this conveyor structure ranges from 0.1828 - 0.3028 mm/year. This value is included in the good category based on the relative corrosion resistance of steel. The residual value of the conveyor structure's service life ranges from 7.19 to 9.65 years. Based on the calculation of the remaining service life of the conveyor structure at 25 test points, there are 24% which are estimated to not be able to reach the design life of 15 years.
Abstrak. Dalam industri pertambangan terdapat alat transportasi untuk melakukan pemindahan material hasil penambangan yaitu dengan menggunakan struktur conveyor. Struktur conveyor terbuat dari baja yang rawan mengalami korosi dan beraksi dengan lingkungan. Korosi dapat menimbulkan suatu kerugian yang dapat mengakibatkan pengurangan ketebalan pada struktur conveyor. Oleh karena itu, perlu dilakukan kegiatan pengendalian hingga monitoring pada struktur conveyor agar mencegah korosi. Penelitian ini bertujuan untuk mengetahui jenis korosi, laju korosi, sisa umur pakai, dan metoda pengendalian pada struktur conveyor. Metodologi penelitian yang digunakan adalah pengukuran pengurangan ketebalan struktur conveyor. Penelitian dilakukan terhadap struktur conveyor dengan panjang 90 meter dan 25 test point. Alat yang digunakan dalam pengukuran ketebalan struktur conveyor yaitu Ultrasonic Thickness Gauge TT 130. Kondisi lingkungan di daerah penelitian yaitu temperatur udara kisaran 31oC - 37oC, sedangkan curah hujan kisaran 6,05 - 11,23 mm/tahun. Jenis korosi yang terjadi pada struktur conveyor ini yaitu korosi merata. Metode pengendalian korosi yang diaplikasikan adalah metode coating dengan primer coating menggunakan Seaguard 5000, intermediate coating menggunakan Sherglass FF, dan top coating menggunakan aliphatic acrylic modified polyurethane. Laju korosi pada struktur conveyor ini berkisar antara 0,1828 - 0,3028 mm/tahun. Nilai tersebut masuk ke dalam kategori good berdasarkan ketahanan korosi relatif baja. Nilai sisa umur pakai struktur conveyor yaitu 7,19 - 9,65 tahun. Berdasarkan dari perhitungan sisa umur pakai struktur conveyor pada 25 test point, terdapat sebesar 24% yang diperkirakan tidak dapat mencapai umur desain yaitu 15 tahun.
摘要。在采矿工业中,有一种运输工具,用于移动采矿材料,如煤炭,使用输送机结构。输送机的结构是由钢制成的,所以它很容易被与环境的反应腐蚀。腐蚀会造成损失,从而导致输送机结构厚度的减少。因此,有必要对输送机结构进行监测观察控制活动,以防止腐蚀。本研究旨在确定输送机结构的腐蚀类型、腐蚀速率、剩余使用寿命和控制方法。采用的研究方法是测量输送机结构的减厚。研究对象是一个长度为90米,地面以上25个测试点的输送机结构。用于测量输送机结构厚度的仪器是TT 130超声波测厚仪。研究区环境条件为气温31℃~ 37℃,降雨量6.05 ~ 11.23 mm/年。在这种输送机结构中发生的腐蚀类型是均匀腐蚀。采用的腐蚀控制方法为涂覆方法,基层涂覆采用Seaguard 5000,中间涂覆采用Sherglass FF,顶涂采用脂肪族丙烯酸改性聚氨酯。这种输送机结构的腐蚀速率范围为0.1828 - 0.3028毫米/年。根据钢的相对耐腐蚀性,该值被列入良好类别。输送机结构使用寿命残值为7.19 ~ 9.65年。通过对25个试验点的输送机结构剩余使用寿命的计算,估计有24%不能达到15年的设计寿命。Abstrak。Dalam工业pertambangan terdapat alat transport untuk melakukan permindahan物料hasil penambangan yaitdengan menggunakan结构输送机。输送带输送带达里巴哈杨拉万门加拉米korosi丹beraksi登甘lingkungan。Korosi dapat menimbulkan suatu kerugian yang dapat mengakibatkan pengurangan ketebalan pada罢工输送机。Oleh karena itu, perlu dilakukan kegiatan pengendalian hingga监测pada结构输送机agar menegah korosi。Penelitian ini bertujuan untuk mengetahui jenis korosi, laju korosi, sisa umur pakai, dan mettoda pengen大连padada结构输送机。[方法]penelitian yang digunakan adalah pengukuran pengurangan kettebalan构造输送机。Penelitian dilakukan terhadap structure输送机登安panjang 90米丹25试验点。Alat yang digunakan dalam企鹅ketebalan结构输送机yitu超声波测厚仪tt130。Kondisi lingkungan di daerah penelitian yitu温度udara kisaran 31oC - 37oC, sedangkan curah hujan kisaran 6,05 - 11,23 mm/tahun。Jenis korosi yang terjadi pada结构输送机在yitu korosi merata。涂布方法包括底漆蒙古那坎Seaguard 5000,中间漆蒙古那坎Sherglass FF,丹面漆蒙古那坎脂肪族丙烯酸改性聚氨酯。拉ju korosi板式结构输送机在berkisar antara 0,1828 - 0,3028 mm/tahun。Nilai tersebut masuk ke dalam kategori good berdasarkan ketahanan korosi relative baja。Nilai sisa - umur - pakai结构输送机yitu 7,19 - 9,65 tahun。Berdasarkan dari perhitungan sisa umur pakai结构输送机pada 25测试点,terdapatsebesar 24% yang diperkirakan dada dapatmancapai umur desain yaitu 15 tahun。