Fuzzy inference system for risk classification on polluted insulator strings of high voltage transmission lines

Hilton Oliveira de Lima, S. C. Oliveira, E. Fontana
{"title":"Fuzzy inference system for risk classification on polluted insulator strings of high voltage transmission lines","authors":"Hilton Oliveira de Lima, S. C. Oliveira, E. Fontana","doi":"10.1109/IMOC.2011.6169370","DOIUrl":null,"url":null,"abstract":"Partial discharges on high voltage insulator surfaces are directly related with the deposition of pollution over the insulators. A complete partial discharge sensor network was previously developed and has been in operation for approximately one year. This paper presents the initial analysis of one year long experiments. A fuzzy inference system was applied on the results to extract a risk level. The risk level was incremented and decremented according to the partial discharge activity and relative humidity levels. The risk level obtained in this can be used to better plan the schedules for preventive maintenance.","PeriodicalId":179351,"journal":{"name":"2011 SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC 2011)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC 2011)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMOC.2011.6169370","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

Partial discharges on high voltage insulator surfaces are directly related with the deposition of pollution over the insulators. A complete partial discharge sensor network was previously developed and has been in operation for approximately one year. This paper presents the initial analysis of one year long experiments. A fuzzy inference system was applied on the results to extract a risk level. The risk level was incremented and decremented according to the partial discharge activity and relative humidity levels. The risk level obtained in this can be used to better plan the schedules for preventive maintenance.
高压输电线路污染绝缘子串风险分类模糊推理系统
高压绝缘子表面的局部放电与绝缘子上的污染沉积有直接关系。一个完整的局部放电传感器网络已经开发并运行了大约一年。本文介绍了为期一年的实验的初步分析。对结果应用模糊推理系统提取风险等级。风险等级根据局部排放活动性和相对湿度水平增减。由此获得的风险等级可用于更好地计划预防性维护的进度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信