{"title":"Device Design of Ankle Joint Stretching System Controlled by the Healthy Side Ankle Joint Movement for Self-Rehabilitation","authors":"H. Toda, H. Kawamoto","doi":"10.20965/jrm.2023.p0556","DOIUrl":null,"url":null,"abstract":"An ankle joint stretching device controlled by healthy-side ankle movements was developed for self-rehabilitation. Physical therapists treat their patients to prevent a subject ankle joint’s contracture and improve their walking function. However, sufficient rehabilitation therapy cannot be performed because of the labor demands of ankle joint rehabilitation. There has long been a demand for a self-rehabilitation system to reduce the amount of labor required, with the rehabilitation system operated by a physical therapist using a machine. Self-rehabilitation has not yet been realized. By stretching the affected ankle through the movement of the ankle on the healthy side, a self-rehabilitation device that can be used according to the will of the patient can be developed. An experiment confirmed that the device can realize affected-side ankle joint stretching by moving a foot plate connected to a linear actuator using the angle of the healthy-side ankle joint as a trigger. Ankle joint rotation angles of the affected and healthy sides were measured using two acceleration sensors. Compared with the previously used button-push-type control, healthy-side control can realize a smooth and stable affected-side sole-pushing procedure. The proposed system, which does not require operation by a physical therapist during treatment, makes self-rehabilitation of the ankle joint possible.","PeriodicalId":178614,"journal":{"name":"J. Robotics Mechatronics","volume":"04 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"J. Robotics Mechatronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20965/jrm.2023.p0556","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

An ankle joint stretching device controlled by healthy-side ankle movements was developed for self-rehabilitation. Physical therapists treat their patients to prevent a subject ankle joint’s contracture and improve their walking function. However, sufficient rehabilitation therapy cannot be performed because of the labor demands of ankle joint rehabilitation. There has long been a demand for a self-rehabilitation system to reduce the amount of labor required, with the rehabilitation system operated by a physical therapist using a machine. Self-rehabilitation has not yet been realized. By stretching the affected ankle through the movement of the ankle on the healthy side, a self-rehabilitation device that can be used according to the will of the patient can be developed. An experiment confirmed that the device can realize affected-side ankle joint stretching by moving a foot plate connected to a linear actuator using the angle of the healthy-side ankle joint as a trigger. Ankle joint rotation angles of the affected and healthy sides were measured using two acceleration sensors. Compared with the previously used button-push-type control, healthy-side control can realize a smooth and stable affected-side sole-pushing procedure. The proposed system, which does not require operation by a physical therapist during treatment, makes self-rehabilitation of the ankle joint possible.
健康侧踝关节运动控制的自我康复踝关节伸展系统装置设计
研制了一种健康侧踝关节运动控制的踝关节伸展装置,用于自我康复。物理治疗师治疗他们的病人,以防止受试者踝关节挛缩和改善他们的行走功能。然而,由于踝关节康复的劳动需求,无法进行充分的康复治疗。长期以来,人们一直需要一种自我康复系统,以减少所需的劳动量,康复系统由物理治疗师使用机器操作。自我康复尚未实现。通过健康侧踝关节的运动来拉伸受影响的踝关节,可以开发出一种可以根据患者意愿使用的自我康复装置。实验证实,该装置以健康侧踝关节角度为触发点,通过移动与线性执行器相连的足板,实现患侧踝关节的拉伸。用两个加速度传感器测量患侧和健康侧踝关节旋转角度。与以往使用的按键式控制相比,健康侧控制可以实现平稳、稳定的患侧推底过程。该系统在治疗过程中不需要物理治疗师的操作,使踝关节的自我康复成为可能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信