Reducing the Number of Central Inverters of a Photovoltaic Plant Using Medium-Voltage Capacitor Banks

Loai Al-Adim, Mehrdad Aliasgari, M. Mozumdar, Saleh Al Jufout
{"title":"Reducing the Number of Central Inverters of a Photovoltaic Plant Using Medium-Voltage Capacitor Banks","authors":"Loai Al-Adim, Mehrdad Aliasgari, M. Mozumdar, Saleh Al Jufout","doi":"10.1109/IGESSC55810.2022.9955335","DOIUrl":null,"url":null,"abstract":"This paper investigates the effect of Medium-Voltage (MV) capacitor banks on the number of central inverters of grid-connected Photovoltaic (PV) plants. All generators including renewable energy sources must meet the Intermit Renewable Resource (IRR)–Transmission Interconnection Code (TIC). To comply with this code, the number of central inverters of the grid-connected PV plant must be increased, which leads to additional costs. In this paper, three cases of a 200-MW gridconnected PV plant were investigated. These cases are with and without increasing the number of the central inverters; while the third case is by adding MV capacitor banks to meet the grid code requirements. In this paper, calculations have been performed using ETAP software for all cases. The P-Q capability curves have been discussed for all cases.","PeriodicalId":166147,"journal":{"name":"2022 IEEE Green Energy and Smart System Systems(IGESSC)","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE Green Energy and Smart System Systems(IGESSC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IGESSC55810.2022.9955335","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper investigates the effect of Medium-Voltage (MV) capacitor banks on the number of central inverters of grid-connected Photovoltaic (PV) plants. All generators including renewable energy sources must meet the Intermit Renewable Resource (IRR)–Transmission Interconnection Code (TIC). To comply with this code, the number of central inverters of the grid-connected PV plant must be increased, which leads to additional costs. In this paper, three cases of a 200-MW gridconnected PV plant were investigated. These cases are with and without increasing the number of the central inverters; while the third case is by adding MV capacitor banks to meet the grid code requirements. In this paper, calculations have been performed using ETAP software for all cases. The P-Q capability curves have been discussed for all cases.
利用中压电容器组减少光伏电站中央逆变器的数量
本文研究了中压电容器组对并网光伏电站中心逆变器数量的影响。包括可再生能源在内的所有发电机必须符合间歇性可再生资源(IRR) -传输互连规范(TIC)。为了遵守这一规范,必须增加并网光伏电站的中央逆变器数量,这将导致额外的成本。本文以200mw并网光伏电站为例进行了研究。这些情况是有和没有增加中央逆变器的数量;而第三种情况是通过增加中压电容器组来满足电网规范的要求。本文使用ETAP软件对所有情况进行了计算。讨论了所有情况下的P-Q能力曲线。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信