Calibration and adjustment of an eddy current based multi-sensor probe for non- destructive testing

G. Betta, L. Ferrigno, M. Laracca
{"title":"Calibration and adjustment of an eddy current based multi-sensor probe for non- destructive testing","authors":"G. Betta, L. Ferrigno, M. Laracca","doi":"10.1109/SFICON.2002.1159819","DOIUrl":null,"url":null,"abstract":"In this paper an easy way to calibrate and adjust the output response of a multi-sensor probe for non-destructive testing on conductive material is proposed in order to perform the calibration, a simple coil is used, considered as a reference magnetic field generator thanking to a preliminary characterization carried out by using a simulation software. An FFT based algorithm was then used for probe adjustment. The calibration and adjustment apparatus can be easily integrated in the realized multi-sensor probe, so realizing a self-calibrating NDT instrument. The realized probe has then been tested on specimen with known cracks and the experimental results have been compared with the theoretical ones showing a very good agreement.","PeriodicalId":294424,"journal":{"name":"2nd ISA/IEEE Sensors for Industry Conference,","volume":"81 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2nd ISA/IEEE Sensors for Industry Conference,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SFICON.2002.1159819","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

In this paper an easy way to calibrate and adjust the output response of a multi-sensor probe for non-destructive testing on conductive material is proposed in order to perform the calibration, a simple coil is used, considered as a reference magnetic field generator thanking to a preliminary characterization carried out by using a simulation software. An FFT based algorithm was then used for probe adjustment. The calibration and adjustment apparatus can be easily integrated in the realized multi-sensor probe, so realizing a self-calibrating NDT instrument. The realized probe has then been tested on specimen with known cracks and the experimental results have been compared with the theoretical ones showing a very good agreement.
基于涡流的多传感器无损检测探头的校准和调整
本文提出了一种简便的方法来校准和调整用于导电材料无损检测的多传感器探头的输出响应,为了进行校准,使用了一个简单的线圈,作为参考磁场发生器,并通过仿真软件进行了初步表征。然后使用基于FFT的算法对探头进行调整。校准和调整装置可以很容易地集成在已实现的多传感器探头中,从而实现自校准无损检测仪器。在已知裂纹的试样上进行了试验,并与理论结果进行了比较,结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信