Design of Mass-Sensitive Sensor Array for Biomedical Application: Sensing Lipoproteins

Suticha Chunta, P. Lieberzeit
{"title":"Design of Mass-Sensitive Sensor Array for Biomedical Application: Sensing Lipoproteins","authors":"Suticha Chunta, P. Lieberzeit","doi":"10.1109/IBIOMED.2018.8534925","DOIUrl":null,"url":null,"abstract":"Herein we report the design of a novel sensor array based on molecularly imprinted polymer (MIP) for lowdensity lipoprotein (LDL) and high-density lipoprotein (HDL) determination. MIP of each lipoprotein class comprising comonomer of methacrylic acid (MAA) and vinyl pyrrolidone (NVP) in the ratio of 3:2 and 2:3, were screened onto threeelectrode quartz crystal microbalance (QCM) as selective elements toward LDL and HDL, respectively. Sensor array device reveals concentration-dependent sensor responses toward varying amount of each standard LDL and HDL solution with a linear correlation coefficient of R$^{2} =$ 0.89 and 0.99, respectively. HDL-MIP presents cross-reactivity to LDL at 9-19% compared to the LDL-MIP signal. LDL-MIP also has cross-reactivity to HDL at 0-3% of LDL-MIP responses. All sensor signals are fully reversible and the sensor array can be reused.","PeriodicalId":217196,"journal":{"name":"2018 2nd International Conference on Biomedical Engineering (IBIOMED)","volume":"71 11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 2nd International Conference on Biomedical Engineering (IBIOMED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IBIOMED.2018.8534925","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Herein we report the design of a novel sensor array based on molecularly imprinted polymer (MIP) for lowdensity lipoprotein (LDL) and high-density lipoprotein (HDL) determination. MIP of each lipoprotein class comprising comonomer of methacrylic acid (MAA) and vinyl pyrrolidone (NVP) in the ratio of 3:2 and 2:3, were screened onto threeelectrode quartz crystal microbalance (QCM) as selective elements toward LDL and HDL, respectively. Sensor array device reveals concentration-dependent sensor responses toward varying amount of each standard LDL and HDL solution with a linear correlation coefficient of R$^{2} =$ 0.89 and 0.99, respectively. HDL-MIP presents cross-reactivity to LDL at 9-19% compared to the LDL-MIP signal. LDL-MIP also has cross-reactivity to HDL at 0-3% of LDL-MIP responses. All sensor signals are fully reversible and the sensor array can be reused.
生物医学应用质量敏感传感器阵列的设计:检测脂蛋白
本文报道了一种基于分子印迹聚合物(MIP)的新型传感器阵列的设计,用于检测低密度脂蛋白(LDL)和高密度脂蛋白(HDL)。在三电极石英晶体微天平(QCM)上筛选了由甲基丙烯酸(MAA)和乙烯基吡罗烷酮(NVP)组成的共聚单体的MIP,分别作为对LDL和HDL的选择性元件。传感器阵列装置揭示了传感器对不同浓度的LDL和HDL标准溶液的响应,线性相关系数分别为R$^{2} =$ 0.89和0.99。与LDL- mip信号相比,HDL-MIP对LDL表现出9-19%的交叉反应性。LDL-MIP对HDL也有交叉反应,在LDL-MIP应答中占0-3%。所有传感器信号都是完全可逆的,传感器阵列可以重复使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信