{"title":"Design of Mass-Sensitive Sensor Array for Biomedical Application: Sensing Lipoproteins","authors":"Suticha Chunta, P. Lieberzeit","doi":"10.1109/IBIOMED.2018.8534925","DOIUrl":null,"url":null,"abstract":"Herein we report the design of a novel sensor array based on molecularly imprinted polymer (MIP) for lowdensity lipoprotein (LDL) and high-density lipoprotein (HDL) determination. MIP of each lipoprotein class comprising comonomer of methacrylic acid (MAA) and vinyl pyrrolidone (NVP) in the ratio of 3:2 and 2:3, were screened onto threeelectrode quartz crystal microbalance (QCM) as selective elements toward LDL and HDL, respectively. Sensor array device reveals concentration-dependent sensor responses toward varying amount of each standard LDL and HDL solution with a linear correlation coefficient of R$^{2} =$ 0.89 and 0.99, respectively. HDL-MIP presents cross-reactivity to LDL at 9-19% compared to the LDL-MIP signal. LDL-MIP also has cross-reactivity to HDL at 0-3% of LDL-MIP responses. All sensor signals are fully reversible and the sensor array can be reused.","PeriodicalId":217196,"journal":{"name":"2018 2nd International Conference on Biomedical Engineering (IBIOMED)","volume":"71 11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 2nd International Conference on Biomedical Engineering (IBIOMED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IBIOMED.2018.8534925","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Herein we report the design of a novel sensor array based on molecularly imprinted polymer (MIP) for lowdensity lipoprotein (LDL) and high-density lipoprotein (HDL) determination. MIP of each lipoprotein class comprising comonomer of methacrylic acid (MAA) and vinyl pyrrolidone (NVP) in the ratio of 3:2 and 2:3, were screened onto threeelectrode quartz crystal microbalance (QCM) as selective elements toward LDL and HDL, respectively. Sensor array device reveals concentration-dependent sensor responses toward varying amount of each standard LDL and HDL solution with a linear correlation coefficient of R$^{2} =$ 0.89 and 0.99, respectively. HDL-MIP presents cross-reactivity to LDL at 9-19% compared to the LDL-MIP signal. LDL-MIP also has cross-reactivity to HDL at 0-3% of LDL-MIP responses. All sensor signals are fully reversible and the sensor array can be reused.