Mohamed El Maroush, Elmabrouk Eljayir, Sarra Ben Hamida
{"title":"The Effect of Locator Attachment and Ball-O-Ring Attachment on Bone Height Change in Implant Retained Overdenture","authors":"Mohamed El Maroush, Elmabrouk Eljayir, Sarra Ben Hamida","doi":"10.47705/kjdmr.216112","DOIUrl":null,"url":null,"abstract":"Objectives. This study was conducted to evaluate and compare the effect of locator attachment and Ball-O-ring attachment on the peri-implant crestal bone level changes in edentulous patients rehabilitated with implant retained lower over denture. Methods. Twenty edentulous patients (male) were participating in this study, they were rehabilitated by mucosa supported maxillary complete denture and implant retained mandibular over denture by two implants installed in the canine region, patients were divided into two equal groups according to the type of attachment used, the locator attachment was used for group I and Ball-O-ring attachment was used for group II. Peri-implant crestal bone level changes were assessed using intra-oral radiographs taken with the standardized long cone paralleling technique using custom made acrylic template and the Rinn-xcp system. Periapical radiographs were taken every six months to complete a period of 18 months follow up period. The marginal bone loss at different intervals was obtained by calculating the difference in bone height at that interval from the base line measurement and statistically analyzed (t-test P < 0.05). Results. The result of this study showed that the time has significant effect on the mean values of the peri-implant bone height on both groups. Moreover, group I had significantly less bone resorption from insertion to twelve months in compare to group II. Conclusion. The insignificant difference observed between comparing the peri-implant bone loss between the two groups indicates that the two treatment modalities are effective for the rehabilitation of lower denture. Locator attachments have the ability to control the amount bone loss. It could be advantageous in cases where the retention of implants retained overdentures is compromised.","PeriodicalId":436335,"journal":{"name":"Khalij-Libya Journal of Dental and Medical Research","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Khalij-Libya Journal of Dental and Medical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47705/kjdmr.216112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives. This study was conducted to evaluate and compare the effect of locator attachment and Ball-O-ring attachment on the peri-implant crestal bone level changes in edentulous patients rehabilitated with implant retained lower over denture. Methods. Twenty edentulous patients (male) were participating in this study, they were rehabilitated by mucosa supported maxillary complete denture and implant retained mandibular over denture by two implants installed in the canine region, patients were divided into two equal groups according to the type of attachment used, the locator attachment was used for group I and Ball-O-ring attachment was used for group II. Peri-implant crestal bone level changes were assessed using intra-oral radiographs taken with the standardized long cone paralleling technique using custom made acrylic template and the Rinn-xcp system. Periapical radiographs were taken every six months to complete a period of 18 months follow up period. The marginal bone loss at different intervals was obtained by calculating the difference in bone height at that interval from the base line measurement and statistically analyzed (t-test P < 0.05). Results. The result of this study showed that the time has significant effect on the mean values of the peri-implant bone height on both groups. Moreover, group I had significantly less bone resorption from insertion to twelve months in compare to group II. Conclusion. The insignificant difference observed between comparing the peri-implant bone loss between the two groups indicates that the two treatment modalities are effective for the rehabilitation of lower denture. Locator attachments have the ability to control the amount bone loss. It could be advantageous in cases where the retention of implants retained overdentures is compromised.
目标。本研究旨在评价和比较定位器附着体和球- o -环附着体对无牙义齿患者种植体保留下覆盖义齿修复后种植体周围嵴骨水平变化的影响。方法。本研究选取20例无牙患者(男性),采用黏膜支撑上颌全口义齿和种植体保留下颌覆盖义齿,在犬齿区安装两种种植体,根据使用的附着体类型将患者分为两组,第一组采用定位器附着体,第二组采用球- o -环附着体。采用定制丙烯酸模板和Rinn-xcp系统,采用标准化长锥平行技术拍摄口内x线片,评估种植体周围嵴骨水平变化。根尖周x线片每6个月拍摄一次,随访18个月。通过计算该时间间隔骨高与基线测量值的差值,得出不同时间间隔的边际骨质流失情况,并进行统计学分析(t检验P < 0.05)。结果。本研究结果显示,时间对两组种植体周围骨高度平均值有显著影响。此外,与II组相比,I组从插入到12个月的骨吸收明显减少。结论。两组种植周骨丢失比较差异不显著,说明两种治疗方式对下义齿的康复是有效的。定位器附着物具有控制骨质流失量的能力。在种植体保留覆盖义齿受损的情况下,它是有利的。