{"title":"Study of treatment for distal end radial fractures by open reduction and internal fixation with volar locking compression plates","authors":"V. Patel, V. Pushkarna, Hardik S. Padhiyar","doi":"10.17511/ijoso.2020.i06.02","DOIUrl":null,"url":null,"abstract":"Introduction: For dorsally displaced lower end radius fractures percutaneous pinning fixation and insome studies fragment specific fixation shows their advantages. For volarly displaced fracturesvolarly plate fixation traditionally showed good results. The volar locking plates with their inheritanceability to provide absolute stability are attractive for their advantages. Objective: To assess thefunctional outcome of treating the distal end radius fractures with the use of volar lockingcompression plates. Materials and methods: Study of a total of 30 patients was conducted in thedepartment of orthopedics at G K General Hospital, Bhuj, Gujarat. All 30 patients with closedfractures were included in the study. All patients were treated with open reduction and internalfixation with the use of a volar locking compression plate. The patients were followed up at one, two,three, and up to six months. Mayo wrist scoring system was used to assess final functional outcomesof treatment. Results: At the final functional assessment, as per mayo wrist scoring out of a total of30 patients, 17 of them achieved excellent, 7 achieved good outcomes, with 5 patients exhibitingfair results and one patient had the collapse of fixation at the 3-month review. No, any patient haddiminution of functional outcome. On radiological assessment, 70% of patients had callus formationand no clear fracture line was seen, 18% had callus formation but a visible fracture line was presentand 12% of patients had clear visible fracture line up to final follow up. Conclusion: Open reductionand internal fixation with volar locking compression plating is a safe and effective treatment forunstable especially volarly displaced fractures of distal end radius with satisfactory functionaloutcome.","PeriodicalId":267909,"journal":{"name":"Surgical Update: International Journal of Surgery and Orthopedics","volume":"515 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Update: International Journal of Surgery and Orthopedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17511/ijoso.2020.i06.02","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Introduction: For dorsally displaced lower end radius fractures percutaneous pinning fixation and insome studies fragment specific fixation shows their advantages. For volarly displaced fracturesvolarly plate fixation traditionally showed good results. The volar locking plates with their inheritanceability to provide absolute stability are attractive for their advantages. Objective: To assess thefunctional outcome of treating the distal end radius fractures with the use of volar lockingcompression plates. Materials and methods: Study of a total of 30 patients was conducted in thedepartment of orthopedics at G K General Hospital, Bhuj, Gujarat. All 30 patients with closedfractures were included in the study. All patients were treated with open reduction and internalfixation with the use of a volar locking compression plate. The patients were followed up at one, two,three, and up to six months. Mayo wrist scoring system was used to assess final functional outcomesof treatment. Results: At the final functional assessment, as per mayo wrist scoring out of a total of30 patients, 17 of them achieved excellent, 7 achieved good outcomes, with 5 patients exhibitingfair results and one patient had the collapse of fixation at the 3-month review. No, any patient haddiminution of functional outcome. On radiological assessment, 70% of patients had callus formationand no clear fracture line was seen, 18% had callus formation but a visible fracture line was presentand 12% of patients had clear visible fracture line up to final follow up. Conclusion: Open reductionand internal fixation with volar locking compression plating is a safe and effective treatment forunstable especially volarly displaced fractures of distal end radius with satisfactory functionaloutcome.