S. Abbas, M. A. Naeem, Abid Ali, Sadia Azam, Atika Hasan, Syeda Doaa Zainab, Waseem Zafar
{"title":"Detection of Cerebral Aneurysm in Cerebral Arteries Following Non-Invasive CT Angiogram","authors":"S. Abbas, M. A. Naeem, Abid Ali, Sadia Azam, Atika Hasan, Syeda Doaa Zainab, Waseem Zafar","doi":"10.36349/easjrit.2022.v04i03.008","DOIUrl":null,"url":null,"abstract":"Background: Cerebral aneurysm is the basic cause of sub-arachnoid hemorrhage; Computed tomographic angiogram is the non-invasive approach to diagnose aneurysm by reconstructing the image in 3D dimension making it possible to locate the aneurysm and differentiate it from other arteries. Objective: Focus of this study was to investigate the accuracy of CTA to detect the aneurysm, its type, location and size. Material and method: Data of 50 patients was taken retrospectively with cost-benefit approach that undergoes non-invasive CTA through Aquilion 64-slices CT machine under post-processing work station. Results: This retrospective study is taken with 50 patients, with a 38 percent positive predictive value and a 62 percent negative predictive value, multi-slice CT properly revealed substantial aneurysm in 19 of 50 cases. Conclusion: 64-slices CT provides high diagnostic accuracy for detecting the aneurysm in cerebral arteries with a non-invasive angiogram procedure.","PeriodicalId":429686,"journal":{"name":"EAS Journal of Radiology and Imaging Technology","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EAS Journal of Radiology and Imaging Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36349/easjrit.2022.v04i03.008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Cerebral aneurysm is the basic cause of sub-arachnoid hemorrhage; Computed tomographic angiogram is the non-invasive approach to diagnose aneurysm by reconstructing the image in 3D dimension making it possible to locate the aneurysm and differentiate it from other arteries. Objective: Focus of this study was to investigate the accuracy of CTA to detect the aneurysm, its type, location and size. Material and method: Data of 50 patients was taken retrospectively with cost-benefit approach that undergoes non-invasive CTA through Aquilion 64-slices CT machine under post-processing work station. Results: This retrospective study is taken with 50 patients, with a 38 percent positive predictive value and a 62 percent negative predictive value, multi-slice CT properly revealed substantial aneurysm in 19 of 50 cases. Conclusion: 64-slices CT provides high diagnostic accuracy for detecting the aneurysm in cerebral arteries with a non-invasive angiogram procedure.