[Tensile strength of the bond to In-ceram after varying modes of surface conditioning].

Deutsche zahnarztliche Zeitschrift Pub Date : 1991-11-01
M Kern, M J Neikes, J R Strub
{"title":"[Tensile strength of the bond to In-ceram after varying modes of surface conditioning].","authors":"M Kern,&nbsp;M J Neikes,&nbsp;J R Strub","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The tensile bond strengths of six different resin-bonding-systems to the aluminium oxide ceramic In-Ceram were tested. The samples were stored in artificial saliva (37 degrees C) up to 150 days and thermocycled (5 degrees-55 degrees C, 18,750 cycles). After sandblasting or silicoating of In-Ceram the tensile bond strength of the modified Bis-GMA resin Panavia-Ex showed no significant changes within this observation period. Using the conventional Bis-GMA resin Microfill-pontic, silicoating In-Ceram with the Rocatec-system resulted in a better bond strength than the use of a silane. The used etching procedure with boiling 70% sulphuric acid was proven to be unsuitable for a long-term stable bond.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche zahnarztliche Zeitschrift","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The tensile bond strengths of six different resin-bonding-systems to the aluminium oxide ceramic In-Ceram were tested. The samples were stored in artificial saliva (37 degrees C) up to 150 days and thermocycled (5 degrees-55 degrees C, 18,750 cycles). After sandblasting or silicoating of In-Ceram the tensile bond strength of the modified Bis-GMA resin Panavia-Ex showed no significant changes within this observation period. Using the conventional Bis-GMA resin Microfill-pontic, silicoating In-Ceram with the Rocatec-system resulted in a better bond strength than the use of a silane. The used etching procedure with boiling 70% sulphuric acid was proven to be unsuitable for a long-term stable bond.

[不同表面处理模式后与In-ceram的粘结强度]。
测试了6种不同的树脂粘接体系对氧化铝陶瓷In-Ceram的拉伸强度。样品在人工唾液(37℃)中保存150天,并进行热循环(5℃-55℃,18,750次循环)。在对In-Ceram进行喷砂或硅化处理后,改性Bis-GMA树脂Panavia-Ex的抗拉强度在观察期内没有明显变化。使用传统的Bis-GMA微填充树脂,将in - ceram与rocatec系统相结合,比使用硅烷具有更好的结合强度。用沸腾的70%硫酸刻蚀的方法不适合形成长期稳定的键。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信