[The dimensional stability of hydrophilic impression materials after application of a disinfectant].

Deutsche zahnarztliche Zeitschrift Pub Date : 1991-11-01
R Stoll, F Segschneider, V Stachniss, R Jürgensen
{"title":"[The dimensional stability of hydrophilic impression materials after application of a disinfectant].","authors":"R Stoll,&nbsp;F Segschneider,&nbsp;V Stachniss,&nbsp;R Jürgensen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The influence of a disinfectant solution containing glutaraldehyde on the dimensional stability of 2 alginate and 4 elastomeric impression materials has been investigated. Die models were measured using a computer-controlled method and compared to the master die to assess the three-dimensional change in the impression material. After an immersion time of 10 min, a dimensional change did not occur. When using immersion times longer than 10 min, the accuracy of the alginate materials was generally more affected by the disinfecting solution than that of the elastomeric impression materials.</p>","PeriodicalId":11244,"journal":{"name":"Deutsche zahnarztliche Zeitschrift","volume":"46 11","pages":"718-21"},"PeriodicalIF":0.0000,"publicationDate":"1991-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Deutsche zahnarztliche Zeitschrift","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The influence of a disinfectant solution containing glutaraldehyde on the dimensional stability of 2 alginate and 4 elastomeric impression materials has been investigated. Die models were measured using a computer-controlled method and compared to the master die to assess the three-dimensional change in the impression material. After an immersion time of 10 min, a dimensional change did not occur. When using immersion times longer than 10 min, the accuracy of the alginate materials was generally more affected by the disinfecting solution than that of the elastomeric impression materials.

[使用消毒剂后亲水压印材料的尺寸稳定性]。
研究了戊二醛消毒液对2种海藻酸盐和4种弹性体印模材料尺寸稳定性的影响。模具模型使用计算机控制的方法进行测量,并与主模具进行比较,以评估压模材料的三维变化。浸泡10分钟后,尺寸没有发生变化。当浸泡时间超过10 min时,海藻酸盐材料的精度一般比弹性体印模材料受消毒液的影响更大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信