Microprocessor-based distance relay

F.M.A. Hussain, N. Khan, N. Mariun, S. Mahmod
{"title":"Microprocessor-based distance relay","authors":"F.M.A. Hussain, N. Khan, N. Mariun, S. Mahmod","doi":"10.1109/PECON.2003.1437414","DOIUrl":null,"url":null,"abstract":"This paper presents the design and operation algorithm for the protection of short transmission line using microprocessor-based distance relay. The characteristic of a distance relay is realised by comparing voltage and current at the relay location. The ratio of voltage (V) to current (I) gives the impedance of the line section between the relay location and the fault point. The signal will be taken from the transmission line and it will be converted to digital signal then goes to the microprocessor which has a program written in assembly language to estimate the apparent impedance of the protected line, the calculated impedance is capered to the replica set impedance inside the relay to decide a trip command. The decision will be made according to this signal whether there is a fault or not.","PeriodicalId":136640,"journal":{"name":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2003-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings. National Power Engineering Conference, 2003. PECon 2003.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PECON.2003.1437414","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper presents the design and operation algorithm for the protection of short transmission line using microprocessor-based distance relay. The characteristic of a distance relay is realised by comparing voltage and current at the relay location. The ratio of voltage (V) to current (I) gives the impedance of the line section between the relay location and the fault point. The signal will be taken from the transmission line and it will be converted to digital signal then goes to the microprocessor which has a program written in assembly language to estimate the apparent impedance of the protected line, the calculated impedance is capered to the replica set impedance inside the relay to decide a trip command. The decision will be made according to this signal whether there is a fault or not.
基于微处理器的距离继电器
本文提出了一种基于单片机的距离继电器保护短线的设计和操作算法。距离继电器的特性是通过比较继电器位置的电压和电流来实现的。电压(V)与电流(I)之比给出了继电器位置和故障点之间的线路截面的阻抗。从传输线上取信号,将其转换成数字信号,然后送到微处理器,微处理器用汇编语言编写程序,估计被保护线的视阻抗,计算出的阻抗跳传给继电器内部的复设阻抗,以决定跳闸命令。根据这个信号判断是否有故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信