{"title":"Augmented heat transfer in rectangular duct with angled Z-shaped ribs","authors":"M. Pimsarn, Parkpoom Sriromreun, P. Promvonge","doi":"10.1109/ESD.2010.5598858","DOIUrl":null,"url":null,"abstract":"An experiment is focused on the design of the suitable ribs used for enhancing heat transfer in a rectangular duct heat exchanger by using wall heat transfer (Nusselt number), friction loss (friction factor) and thermal performance (thermal enhancement factor) data. The Z-shaped ribs were set on the rectangular duct at 30°, 45° and 60° and flat rib was set at 90° relative to the air flow direction. Reynolds numbers studied ranging from 5000 to 25,000 in the test section. The rectangular duct has aspect ratio, AR = 10 and height, H = 30 mm with the Z-rib height (e), e/H = 0.2 and the rib pitch (P), P/H = 3. The ribs were fitted in Z-shape (Z-rib) aligned in series on the whole area of the upper plate. The results of the Z-ribs show the significant increase in heat transfer rate and friction loss over the smooth channel. The 45° Z-rib provides the highest increase in the heat transfer rate and the best thermal performance","PeriodicalId":272782,"journal":{"name":"Proceedings of the International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESD.2010.5598858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
An experiment is focused on the design of the suitable ribs used for enhancing heat transfer in a rectangular duct heat exchanger by using wall heat transfer (Nusselt number), friction loss (friction factor) and thermal performance (thermal enhancement factor) data. The Z-shaped ribs were set on the rectangular duct at 30°, 45° and 60° and flat rib was set at 90° relative to the air flow direction. Reynolds numbers studied ranging from 5000 to 25,000 in the test section. The rectangular duct has aspect ratio, AR = 10 and height, H = 30 mm with the Z-rib height (e), e/H = 0.2 and the rib pitch (P), P/H = 3. The ribs were fitted in Z-shape (Z-rib) aligned in series on the whole area of the upper plate. The results of the Z-ribs show the significant increase in heat transfer rate and friction loss over the smooth channel. The 45° Z-rib provides the highest increase in the heat transfer rate and the best thermal performance