{"title":"Design of DC system protection","authors":"A. H. Chang, A. Avestruz, S. Leeb, J. Kirtley","doi":"10.1109/ESTS.2013.6523783","DOIUrl":null,"url":null,"abstract":"A modified Z-source breaker topology is introduced to minimize the reflected fault current drawn from a source while retaining a common return ground path. A conventional Z-source breaker does not provide steady-state overload protection and can only guard against extremely large transient faults. The Z-source breaker can be designed for considerations affecting both rate of fault current rise and absolute fault current level, analogous in some respects to a “thermal-magnetic” breaker. The proposed manual tripping mechanism enables protection against both instantaneous current surges and longer-term over-current conditions. The fault operation intervals of the proposed Z-source breaker topologies are demonstrated in SPICE simulation.","PeriodicalId":119318,"journal":{"name":"2013 IEEE Electric Ship Technologies Symposium (ESTS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"34","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Electric Ship Technologies Symposium (ESTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTS.2013.6523783","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 34

Abstract

A modified Z-source breaker topology is introduced to minimize the reflected fault current drawn from a source while retaining a common return ground path. A conventional Z-source breaker does not provide steady-state overload protection and can only guard against extremely large transient faults. The Z-source breaker can be designed for considerations affecting both rate of fault current rise and absolute fault current level, analogous in some respects to a “thermal-magnetic” breaker. The proposed manual tripping mechanism enables protection against both instantaneous current surges and longer-term over-current conditions. The fault operation intervals of the proposed Z-source breaker topologies are demonstrated in SPICE simulation.
直流系统保护设计
一种改进的z源断路器拓扑被引入,以最小化从一个源引出的反射故障电流,同时保留一个共同的返回地路径。传统的z源断路器不提供稳态过载保护,只能防止极大的瞬态故障。z源断路器的设计可以考虑影响故障电流上升速率和绝对故障电流水平,在某些方面类似于“热磁”断路器。提议的手动跳闸机制可以防止瞬时电流浪涌和长期过流情况。在SPICE仿真中验证了所提出的z源断路器拓扑的故障运行间隔。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信