Nitrogen-Doped Graphene Supported α-Co(OH)2 for Sensitive Determination of Adrenaline

IF 1.9
Abdul Kader Mohiuddin, S. Jeon
{"title":"Nitrogen-Doped Graphene Supported α-Co(OH)2 for Sensitive Determination of Adrenaline","authors":"Abdul Kader Mohiuddin, S. Jeon","doi":"10.1149/2754-2734/ac948d","DOIUrl":null,"url":null,"abstract":"For a happy and healthy life, there should have a balance of flight-to-flight hormones, i.e., adrenaline (AD). The necessity of determination of AD is inevitable for the diagnosis of associated diseases with it. For this purpose, N-doped graphene supported α-Co(OH)2 (denoted as NrGO/α-Co(OH)2) was synthesized via a hydrothermal process, where α-Co(OH)2 acted as an active site and NrGO provided a better defective surface for immobilized α-Co(OH)2 nanoparticles. The as-prepared nanocomposite altered the electronic configuration due to its defective nature, which played an important role to increase the stability, surface area and electron transfer capability. As a result, NrGO/α-Co(OH)2 demonstrated remarkable analytical performances toward AD with a lower limit of detection (14.7 nM), wide linear range (0.5–800 μM), and good sensitivity (115.983 μA mM−1 cm−2). The CA response time was obtained as 2.2 s. The proposed sensor showed precious selectivity during AD detection in presence of coexisting biomolecules such as DA, AA, UA, TY, 5-HT, and NE, and 50-fold excess of common ions such as Na+, K+, Ca2+, Mn2+, Fe2+, CO3 2−, and SO4 2−. Furthermore, it also provided long-term stability, good reproducibility and repeatability with practical feasibility in the urine sample. Importantly, the effect of pH was studied in detail on AD oxidation.","PeriodicalId":338397,"journal":{"name":"ECS Advances","volume":"23 1","pages":"0"},"PeriodicalIF":1.9000,"publicationDate":"2022-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS Advances","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/2754-2734/ac948d","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

For a happy and healthy life, there should have a balance of flight-to-flight hormones, i.e., adrenaline (AD). The necessity of determination of AD is inevitable for the diagnosis of associated diseases with it. For this purpose, N-doped graphene supported α-Co(OH)2 (denoted as NrGO/α-Co(OH)2) was synthesized via a hydrothermal process, where α-Co(OH)2 acted as an active site and NrGO provided a better defective surface for immobilized α-Co(OH)2 nanoparticles. The as-prepared nanocomposite altered the electronic configuration due to its defective nature, which played an important role to increase the stability, surface area and electron transfer capability. As a result, NrGO/α-Co(OH)2 demonstrated remarkable analytical performances toward AD with a lower limit of detection (14.7 nM), wide linear range (0.5–800 μM), and good sensitivity (115.983 μA mM−1 cm−2). The CA response time was obtained as 2.2 s. The proposed sensor showed precious selectivity during AD detection in presence of coexisting biomolecules such as DA, AA, UA, TY, 5-HT, and NE, and 50-fold excess of common ions such as Na+, K+, Ca2+, Mn2+, Fe2+, CO3 2−, and SO4 2−. Furthermore, it also provided long-term stability, good reproducibility and repeatability with practical feasibility in the urine sample. Importantly, the effect of pH was studied in detail on AD oxidation.
氮掺杂石墨烯负载α-Co(OH)2灵敏测定肾上腺素
为了幸福和健康的生活,应该有一个平衡的飞行荷尔蒙,即肾上腺素(AD)。检测AD的必要性对于AD相关疾病的诊断是必然的。为此,通过水热法合成了n掺杂石墨烯负载α-Co(OH)2(表示为NrGO/α-Co(OH)2),其中α-Co(OH)2作为活性位点,NrGO为固定α-Co(OH)2纳米粒子提供了更好的缺陷表面。所制备的纳米复合材料由于其缺陷性质而改变了电子构型,这对提高其稳定性、比表面积和电子转移能力起着重要作用。结果表明,NrGO/α-Co(OH)2具有良好的检测下限(14.7 nM)、宽线性范围(0.5 ~ 800 μM)和良好的灵敏度(115.983 μA mM−1 cm−2)。CA响应时间为2.2 s。该传感器在共存的生物分子(如DA、AA、UA、TY、5-HT和NE)和超过50倍的常见离子(如Na+、K+、Ca2+、Mn2+、Fe2+、co32−和SO4 2−)存在下的AD检测中表现出宝贵的选择性。该方法长期稳定,重现性和重复性好,在尿样中具有实际可行性。重要的是,详细研究了pH对AD氧化的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书