{"title":"A Compound Control Strategy for Inverter Output Voltage in Micro-grid System","authors":"Jinghua Zhou, Rong Zhang, Xinlei Zhang, Jiewei Wu, Weichao Huang","doi":"10.1109/SPEC.2018.8635643","DOIUrl":null,"url":null,"abstract":"For poor inverter output voltage quality caused by operation of asymmetric load and nonlinear load in the micro-grid system, a compound control strategy for inverter output voltage was proposed; in this paper, based on positive sequence rotating coordinate system, Proportion Integrator (PI)+ Vector Proportion Integrator (VPI) controller was used to control fundamental voltage and unbalanced voltage. And based on two-phase static coordinate system, VPI controller was used to control harmonic voltage to finally realize voltage quality governance. In addition, DC/AC + z-type grounding transformer topology was adopted to solve supporting problem of single-phase load by a three-phase three-wire inverter. Finally, a 2.5MW converter device was established to carry out an experimental study based on TMS320F28377D controller. The experimental result verified effectiveness of the proposed control strategy. At present, this device has been applied to flexible substation system in Aliyun data center located in Zhangbei County, Zhangjiakou City, China.","PeriodicalId":335893,"journal":{"name":"2018 IEEE 4th Southern Power Electronics Conference (SPEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE 4th Southern Power Electronics Conference (SPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SPEC.2018.8635643","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

For poor inverter output voltage quality caused by operation of asymmetric load and nonlinear load in the micro-grid system, a compound control strategy for inverter output voltage was proposed; in this paper, based on positive sequence rotating coordinate system, Proportion Integrator (PI)+ Vector Proportion Integrator (VPI) controller was used to control fundamental voltage and unbalanced voltage. And based on two-phase static coordinate system, VPI controller was used to control harmonic voltage to finally realize voltage quality governance. In addition, DC/AC + z-type grounding transformer topology was adopted to solve supporting problem of single-phase load by a three-phase three-wire inverter. Finally, a 2.5MW converter device was established to carry out an experimental study based on TMS320F28377D controller. The experimental result verified effectiveness of the proposed control strategy. At present, this device has been applied to flexible substation system in Aliyun data center located in Zhangbei County, Zhangjiakou City, China.
微电网逆变器输出电压的复合控制策略
针对微网系统中不对称负载和非线性负载运行导致逆变器输出电压质量差的问题,提出了一种逆变器输出电压的复合控制策略;本文基于正序旋转坐标系,采用比例积分器(PI)+矢量比例积分器(VPI)控制器控制基面电压和不平衡电压。基于两相静态坐标系,采用VPI控制器对谐波电压进行控制,最终实现电压质量治理。此外,采用DC/AC + z型接地变压器拓扑,解决了三相三线制逆变器对单相负载的支撑问题。最后,搭建了一个2.5MW变换器装置,进行了基于TMS320F28377D控制器的实验研究。实验结果验证了所提控制策略的有效性。目前,该装置已应用于中国张家口市张北县阿里云数据中心的柔性变电站系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信