{"title":"Study on calibration of terahertz attenuator","authors":"H. Iida, M. Kinoshita, K. Amemiya","doi":"10.1109/CPEM.2016.7540670","DOIUrl":null,"url":null,"abstract":"This paper presents a preliminary study of terahertz (THz) attenuator calibration by using a THz calorimeter. Highly sensitive calorimeter achieves simple and accurate attenuation calibration at room temperature. The calibration method is based on a power ratio measurement by DC substitution. The attenuation measurement is demonstrated for a metalized-film attenuator at 1 THz using a photomixer as a THz source. The measurement results show good repeatability for attenuation of approximately 3 dB.","PeriodicalId":415488,"journal":{"name":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Conference on Precision Electromagnetic Measurements (CPEM 2016)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CPEM.2016.7540670","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents a preliminary study of terahertz (THz) attenuator calibration by using a THz calorimeter. Highly sensitive calorimeter achieves simple and accurate attenuation calibration at room temperature. The calibration method is based on a power ratio measurement by DC substitution. The attenuation measurement is demonstrated for a metalized-film attenuator at 1 THz using a photomixer as a THz source. The measurement results show good repeatability for attenuation of approximately 3 dB.
太赫兹衰减器的标定研究
本文介绍了用太赫兹量热计标定太赫兹衰减器的初步研究。高灵敏度量热仪在室温下实现简单准确的衰减校准。校准方法是基于直流替换的功率比测量。衰减测量演示了金属化薄膜衰减器在1太赫兹,使用光混合器作为太赫兹源。测量结果表明,衰减约为3db,重复性好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信