Monitoring Pergeseran Tanah Tapak Tower Transmisi PT (PLN) Persero Dengan Menggunakan SMS Sebagai Notifikasi Peringatan

Wahyuni Khabzli
{"title":"Monitoring Pergeseran Tanah Tapak Tower Transmisi PT\n(PLN) Persero Dengan Menggunakan SMS Sebagai Notifikasi\nPeringatan","authors":"Wahyuni Khabzli","doi":"10.35143/elementer.v9i1.5973","DOIUrl":null,"url":null,"abstract":"Landslides are one of the causes of the collapse of the transmission tower of PT PLN (Persero) which caused power outages, therefore monitoring the shifting of the transmission tower tread is very necessary so that power outages due to the collapsed tower can be anticipated faster. In this study the authors made a study to monitor tower shifts by using Ultrasonic sensors and LVDT sensors (Linear Variable Differential Transducer), Ultrasonic sensors function to detect shifts from towers and LVDT sensors function to detect shifts from the left and right tread tower ground. In this research, there are three main sensors, namely 2 LVDT sensors and one Ultasonic sensor - each sensor is placed in a safe position from interference and has the least possibility of being affected by landslides, Ultrasonic sensors read the tower shift towards the sensor mounted on the center side and LVDT sensors read the shift ground tread tower on the left and right side of the tower. The sensor sends the signal then is converted by the ATMega 8535 microcontroller into a millimeter unit for LVDT sensors and centimeter meter for Ultrasonic sensors. To find out the changes that occur in the tower and tower ground. Every change in distance or the occurrence of a microcontroller shift sends event data in the form of tower numbers and tower shift distances from each sensor reading using SMS (Short Message Service) communication. The installed LVDT sensor has a reading accuracy rate of 98,05% for LVDT 1 and 98,98% for LVDT 2 in millimeters and an Ultrasonic sensor has a reading accuracy rate of 99,44% in centimeters.","PeriodicalId":308479,"journal":{"name":"Jurnal Elektro dan Mesin Terapan (ELEMENTER)","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Elektro dan Mesin Terapan (ELEMENTER)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35143/elementer.v9i1.5973","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Landslides are one of the causes of the collapse of the transmission tower of PT PLN (Persero) which caused power outages, therefore monitoring the shifting of the transmission tower tread is very necessary so that power outages due to the collapsed tower can be anticipated faster. In this study the authors made a study to monitor tower shifts by using Ultrasonic sensors and LVDT sensors (Linear Variable Differential Transducer), Ultrasonic sensors function to detect shifts from towers and LVDT sensors function to detect shifts from the left and right tread tower ground. In this research, there are three main sensors, namely 2 LVDT sensors and one Ultasonic sensor - each sensor is placed in a safe position from interference and has the least possibility of being affected by landslides, Ultrasonic sensors read the tower shift towards the sensor mounted on the center side and LVDT sensors read the shift ground tread tower on the left and right side of the tower. The sensor sends the signal then is converted by the ATMega 8535 microcontroller into a millimeter unit for LVDT sensors and centimeter meter for Ultrasonic sensors. To find out the changes that occur in the tower and tower ground. Every change in distance or the occurrence of a microcontroller shift sends event data in the form of tower numbers and tower shift distances from each sensor reading using SMS (Short Message Service) communication. The installed LVDT sensor has a reading accuracy rate of 98,05% for LVDT 1 and 98,98% for LVDT 2 in millimeters and an Ultrasonic sensor has a reading accuracy rate of 99,44% in centimeters.
PT输电塔移位监测器使用短信作为警告
山体滑坡是PT PLN (Persero)输电塔倒塌造成停电的原因之一,因此监测输电塔跨距的移动是非常必要的,这样可以更快地预测因塔倒塌造成的停电。在这项研究中,作者研究了利用超声波传感器和LVDT传感器(线性可变差分传感器)来监测塔的位移,超声波传感器用于检测塔的位移,LVDT传感器用于检测塔左右地面的位移。在本研究中,主要有三个传感器,即2个LVDT传感器和1个超声波传感器,每个传感器都放置在不受干扰的安全位置,受山体滑坡影响的可能性最小,超声波传感器读取塔向中心侧安装的传感器的位移,LVDT传感器读取塔左右两侧的地面踏面塔的位移。传感器发送信号,然后由ATMega 8535微控制器转换为LVDT传感器的毫米单位和超声波传感器的厘米单位。找出发生在塔身和塔身地面的变化。距离的每次变化或微控制器移位的发生都以塔号和塔移位距离的形式发送事件数据,这些数据来自使用SMS(短消息服务)通信的每个传感器读数。所安装的LVDT传感器对LVDT 1的读取准确率为98.05%,对LVDT 2的读取准确率为98.98%,以毫米为单位,超声波传感器的读取准确率为99.44%,以厘米为单位。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书