{"title":"Harmonic Analysis of a Third Rail Systems: A Case Study in Malaysia","authors":"K. Chua, Dick Sang Hoo, Y. Lim, Mohammad Babrdelbonab, Li Wang, P. Y. Wong","doi":"10.47890/JEAEE/2020/KEINHUATCHUA/11120010","DOIUrl":null,"url":null,"abstract":"Harmonic distortion is one of the most important power quality issues in third rail electrification systems. The use of rectifiers and inverters in the third rail system can inject a significant amount of harmonic distortion to the electrical network. This paper aims to investigate the harmonic distortions for a DC urban third rail system at various operating conditions. The electrical network of Mass Rapid Transit Line 2 (MRT 2) Malaysia is modelled using ETAP software. The model had considered the effect of the inter-phase transformer in the 12-pulse rectifier. The current injection method is used to measure harmonic distortion at Point of Common Coupling (PCC) at the 132 kV and 33 kV buses. A normal and degraded operating conditions of power supply are investigated. From the simulation results, it is found that the 11th and 13th order harmonics have exceeded the statutory limit at 33 kV network for the normal operating condition. For the degraded operating condition, only the 11th harmonic order has exceeded the statutory limit. Keywords: Harmonic Distortion; DC Urban Rail; Various Operating Conditions","PeriodicalId":423069,"journal":{"name":"Journal of Electronics and Advanced Electrical Engineering","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electronics and Advanced Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47890/JEAEE/2020/KEINHUATCHUA/11120010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Harmonic distortion is one of the most important power quality issues in third rail electrification systems. The use of rectifiers and inverters in the third rail system can inject a significant amount of harmonic distortion to the electrical network. This paper aims to investigate the harmonic distortions for a DC urban third rail system at various operating conditions. The electrical network of Mass Rapid Transit Line 2 (MRT 2) Malaysia is modelled using ETAP software. The model had considered the effect of the inter-phase transformer in the 12-pulse rectifier. The current injection method is used to measure harmonic distortion at Point of Common Coupling (PCC) at the 132 kV and 33 kV buses. A normal and degraded operating conditions of power supply are investigated. From the simulation results, it is found that the 11th and 13th order harmonics have exceeded the statutory limit at 33 kV network for the normal operating condition. For the degraded operating condition, only the 11th harmonic order has exceeded the statutory limit. Keywords: Harmonic Distortion; DC Urban Rail; Various Operating Conditions
第三轨道系统的谐波分析:以马来西亚为例
谐波失真是三轨电气化系统电能质量的重要问题之一。在第三轨系统中使用整流器和逆变器可以向电网注入大量的谐波失真。本文旨在研究直流城市三轨系统在不同运行条件下的谐波畸变。马来西亚地铁2号线(MRT 2)的电力网络使用ETAP软件进行建模。该模型考虑了12脉冲整流器中相间变压器的影响。采用电流注入法测量了132kv和33kv母线共耦合点的谐波畸变。研究了电源的正常运行和劣化运行情况。仿真结果表明,在33kv电网正常运行状态下,11次和13次谐波均超过法定限值。对于退化的运行条件,只有第11次谐波阶超过法定限制。关键词:谐波失真;DC城市轨道;各种操作条件
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书