{"title":"Image Correction Filter for Finger/Palm-print Live Scanner Image","authors":"Y. Isobe, Y. Seto, Yoshitaka Umino","doi":"10.3408/JASTI.4.15","DOIUrl":null,"url":null,"abstract":"We developed a technique that corrects picture quality so that sweat glands on a ridge can be distinguished from the picture obtained by a Finger/Palm-print Live Scanner. The Finger/Palm-print Live Scanner equipment (Live Scanner) has been introduced to the local police stations for fingerprint collection operation. Fingerprint Live Scanner devices have been used as an authentication technology for security systems. The resolution of the Live Scanner image needs to be equal to that of all Live Scanner devices. For example, the required resolution for the police is about 20 points per mm so that sweat glands on a ridge can be distinguished.   We developed a method of image correction to satisfy the requirements for the Live Scanner. Correcting methods for a degraded image such as the inverse filter and the Wiener filter had been proposed. But we are not able to estimate the resolution using the filter designed by these conventional methods. Because these conventional methods use the Signal to Noise ratio as a parameter and don't use relationship to the resolution.   We applied the filter design method that we had developed for a satellite image, to correct the Live Scanner image. The method can evaluate a relationship between the filter effect and the filter parameter by point spread function (PSF). The proposed filter optimization method reduced the full width at half maximum of PSF about 36%, resulting in an improved resolution. With this method, sweat glands on a ridge can be distinguished.","PeriodicalId":134327,"journal":{"name":"Japanese Journal of Science and Technology for Identification","volume":"34 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Science and Technology for Identification","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3408/JASTI.4.15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We developed a technique that corrects picture quality so that sweat glands on a ridge can be distinguished from the picture obtained by a Finger/Palm-print Live Scanner. The Finger/Palm-print Live Scanner equipment (Live Scanner) has been introduced to the local police stations for fingerprint collection operation. Fingerprint Live Scanner devices have been used as an authentication technology for security systems. The resolution of the Live Scanner image needs to be equal to that of all Live Scanner devices. For example, the required resolution for the police is about 20 points per mm so that sweat glands on a ridge can be distinguished.   We developed a method of image correction to satisfy the requirements for the Live Scanner. Correcting methods for a degraded image such as the inverse filter and the Wiener filter had been proposed. But we are not able to estimate the resolution using the filter designed by these conventional methods. Because these conventional methods use the Signal to Noise ratio as a parameter and don't use relationship to the resolution.   We applied the filter design method that we had developed for a satellite image, to correct the Live Scanner image. The method can evaluate a relationship between the filter effect and the filter parameter by point spread function (PSF). The proposed filter optimization method reduced the full width at half maximum of PSF about 36%, resulting in an improved resolution. With this method, sweat glands on a ridge can be distinguished.
图像校正过滤器的手指/掌纹实时扫描仪图像
我们开发了一种校正图像质量的技术,以便将脊上的汗腺与手指/掌纹实时扫描仪获得的图像区分开来。本署已向各警署引进指纹扫描设备,以收集市民的指纹。指纹实时扫描设备已被用作安全系统的认证技术。扫描图像的分辨率需要与所有扫描设备的分辨率相等。例如,警察所需的分辨率约为每毫米20点,以便能够区分山脊上的汗腺。我们开发了一种图像校正方法,以满足实时扫描仪的要求。针对退化图像,提出了反滤波和维纳滤波等校正方法。但是用这些传统方法设计的滤波器无法估计出分辨率。因为这些传统方法使用信噪比作为参数,而不使用与分辨率的关系。我们应用了我们为卫星图像开发的滤波器设计方法来校正Live Scanner图像。该方法可以通过点扩散函数(PSF)来评价滤波效果与滤波参数之间的关系。所提出的滤波器优化方法将PSF的半最大值全宽度减小了约36%,从而提高了分辨率。用这种方法,可以区分脊上的汗腺。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信