Microwave radar sensor as solid flow counter

M. Isa, Z. Wu
{"title":"Microwave radar sensor as solid flow counter","authors":"M. Isa, Z. Wu","doi":"10.1109/HFPSC.2004.1360345","DOIUrl":null,"url":null,"abstract":"Microwave radar sensors (MRS) studies are usually based on the analysis of the frequency response of the reflected signal. A MRS system operating at 10.6 GHz, with computer integration, has been built to study the signal characteristic of solid flows. Beans of /spl lambda//4 in size have been used in this study. The amplitude of the reflected signal has been found to be useful in describing the flow characteristics. The amplitude response can be converted into a digital counter with the application of advance signal processing to eliminate noise and unwanted signals. In fact, the system not only counts the number of solids flowing but was also able to identify the size of the solids. Experimental results are presented in this paper.","PeriodicalId":405718,"journal":{"name":"High Frequency Postgraduate Student Colloquium, 2004","volume":"22 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"High Frequency Postgraduate Student Colloquium, 2004","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/HFPSC.2004.1360345","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Microwave radar sensors (MRS) studies are usually based on the analysis of the frequency response of the reflected signal. A MRS system operating at 10.6 GHz, with computer integration, has been built to study the signal characteristic of solid flows. Beans of /spl lambda//4 in size have been used in this study. The amplitude of the reflected signal has been found to be useful in describing the flow characteristics. The amplitude response can be converted into a digital counter with the application of advance signal processing to eliminate noise and unwanted signals. In fact, the system not only counts the number of solids flowing but was also able to identify the size of the solids. Experimental results are presented in this paper.
微波雷达传感器作为固体流量计数器
微波雷达传感器(MRS)的研究通常基于对反射信号频率响应的分析。为了研究固体流动的信号特性,建立了一个工作在10.6 GHz的具有计算机集成的MRS系统。本研究使用了大小为/spl λ //4的豆类。人们发现反射信号的振幅对描述流动特性是有用的。振幅响应可以转换成数字计数器与应用先进的信号处理,以消除噪声和不需要的信号。事实上,该系统不仅可以计算流动固体的数量,还可以识别固体的大小。本文给出了实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信