ESTIMASI NILAI DOSIS RADIASI EFEKTIF PASIEN DARI CITRA MEDIS CT SCAN ASTEION MULTI 32 SLICE BAGIAN ABDOMEN

Nadiah Wanara, M. Hamdi, Salomo Sinuraya
{"title":"ESTIMASI NILAI DOSIS RADIASI EFEKTIF PASIEN DARI CITRA MEDIS CT SCAN ASTEION MULTI 32 SLICE BAGIAN ABDOMEN","authors":"Nadiah Wanara, M. Hamdi, Salomo Sinuraya","doi":"10.31258/JKFI.17.2.80-86","DOIUrl":null,"url":null,"abstract":"Receipt of radiation doses in patients by CT scan media really contributed to the radio diagnostic field. So far, volume Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) are the dose parameters used as a prescription of the dose to the patients from the examination process on the CT scan. However, these parameters have the disadvantage that they only describe the dose output from the device without regard to patient size. Size Specific Dose Estimate (SSDE) is a dose correction based on patient size and an effective dose is the dose value that arises due to differences in biological sensitivity values. Calculation of SSDE values and total effective doses were carried out in this study from data of patients who had undergone an abdominal CT scan examination. Patient radiation dose data were obtained from documents collected from the Radiology Department at the Prima Pekanbaru hospital. The data was obtained from examination results of Toshiba Asterion Multi (CTB 400 tube) CT scan of the abdomen of 20 patients. The data analysis shows that the average value of SSDE for male and female patients are 19.64 mGy and 17.4 mGy and the average total effective dose for male and female patients are 12.63 mSv and 9.16 mSv. These data indicate that the level of radiation dose received by patients is below the threshold that has been evaluated based on BAPETEN provisions.","PeriodicalId":403286,"journal":{"name":"Komunikasi Fisika Indonesia","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Komunikasi Fisika Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31258/JKFI.17.2.80-86","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Receipt of radiation doses in patients by CT scan media really contributed to the radio diagnostic field. So far, volume Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) are the dose parameters used as a prescription of the dose to the patients from the examination process on the CT scan. However, these parameters have the disadvantage that they only describe the dose output from the device without regard to patient size. Size Specific Dose Estimate (SSDE) is a dose correction based on patient size and an effective dose is the dose value that arises due to differences in biological sensitivity values. Calculation of SSDE values and total effective doses were carried out in this study from data of patients who had undergone an abdominal CT scan examination. Patient radiation dose data were obtained from documents collected from the Radiology Department at the Prima Pekanbaru hospital. The data was obtained from examination results of Toshiba Asterion Multi (CTB 400 tube) CT scan of the abdomen of 20 patients. The data analysis shows that the average value of SSDE for male and female patients are 19.64 mGy and 17.4 mGy and the average total effective dose for male and female patients are 12.63 mSv and 9.16 mSv. These data indicate that the level of radiation dose received by patients is below the threshold that has been evaluated based on BAPETEN provisions.
CT扫描辅助32片腹部切口对患者有效辐射剂量的估计
通过CT扫描介质接收患者的辐射剂量确实对放射诊断领域做出了贡献。到目前为止,体积计算机断层扫描剂量指数(CTDIvol)和剂量长度乘积(DLP)是用来作为CT扫描检查过程中给患者剂量处方的剂量参数。然而,这些参数的缺点是它们只描述设备输出的剂量,而不考虑患者的大小。尺寸特定剂量估计(SSDE)是基于患者尺寸的剂量校正,有效剂量是由于生物敏感性值的差异而产生的剂量值。本研究根据接受腹部CT扫描检查的患者资料计算SSDE值和总有效剂量。患者辐射剂量数据来自普里玛北坎巴鲁医院放射科收集的文件。数据来源于20例患者腹部东芝Asterion Multi (CTB 400管)CT扫描检查结果。数据分析显示,男性和女性患者的SSDE平均值分别为19.64 mGy和17.4 mGy,男性和女性患者的平均总有效剂量分别为12.63 mSv和9.16 mSv。这些数据表明,患者接受的辐射剂量水平低于根据BAPETEN规定评估的阈值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信