{"title":"Eighteen-pulse rectifiers for harmonic mitigation","authors":"S. Kocman, V. Kolář, T. Trung Vo","doi":"10.1109/ICHQP.2010.5625409","DOIUrl":null,"url":null,"abstract":"Multi-pulses rectifiers are one of the technical solutions for harmonic mitigation in AC adjustable speed drives. 12-pulse, 18-pulse and 24-pulse rectifier topologies are used in various technical applications. The paper presents results from experimental measurements and results from simulations for two topologies of the eighteen-pulse rectifiers: with Dy1z1+200z1−200 and with Dd0diii0+200diii0−200 transformers. To simulate the behavior of the both eighteen-pulse rectifiers under various levels of voltage distortion a program written in FORTRAN in EMTP-ATP simulation program has been developed. Both experimental measurements and simulations demonstrate their high harmonic mitigation effectiveness. A comparison of the eighteen-pulse rectifiers with some other techniques for harmonic mitigation is also shown in the paper.","PeriodicalId":180078,"journal":{"name":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 14th International Conference on Harmonics and Quality of Power - ICHQP 2010","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2010.5625409","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
Multi-pulses rectifiers are one of the technical solutions for harmonic mitigation in AC adjustable speed drives. 12-pulse, 18-pulse and 24-pulse rectifier topologies are used in various technical applications. The paper presents results from experimental measurements and results from simulations for two topologies of the eighteen-pulse rectifiers: with Dy1z1+200z1−200 and with Dd0diii0+200diii0−200 transformers. To simulate the behavior of the both eighteen-pulse rectifiers under various levels of voltage distortion a program written in FORTRAN in EMTP-ATP simulation program has been developed. Both experimental measurements and simulations demonstrate their high harmonic mitigation effectiveness. A comparison of the eighteen-pulse rectifiers with some other techniques for harmonic mitigation is also shown in the paper.