Scientific approach for ozone absorption in blood during systemic indirect endovenous ozonetherapy

J. Baeza-Noci, Rosa Pinto-Bonilla, Leonor Contreras-Velasco, Manuel Gomez-Moraleda
{"title":"Scientific approach for ozone absorption in blood during systemic indirect endovenous ozonetherapy","authors":"J. Baeza-Noci, Rosa Pinto-Bonilla, Leonor Contreras-Velasco, Manuel Gomez-Moraleda","doi":"10.7203/JO3T.2.3.2018.9611","DOIUrl":null,"url":null,"abstract":"Introduction. \nReading reference ozone books from Dra. Menendez, Dra. Viebhan, Dra. Borrelli and Dr. Bocci, proper timing for mixing ozone in blood during autohemotherapy is not calculated in a scientific way, having only an estimation of it based on changes in the blood color, more related to oxygen absorption than on ozone itself. \n \nMaterial and methods. \nWe decided to reproduce a reduced model of great autohemotherapy or recently renamed as systemic indirect endovenous ozonotherapy (SIEVO) by the World Federation of Ozone Therapy – WFOT, using syringes to simplify the experiment. Our model consisted of a 20 mL syringe filled with 10 mL of blood withdrawn from healthy volunteers and mixed it gently but in controlled way with 10 mL medical ozone at different concentrations; after 5 and 8 seconds, the remaining gas was analyzed by an spectrophotometer based ozone detector to check the amount of ozone. Data were analyzed using a linear regression model. \n \nResults. \nResults show that even for 60 mcgr/mL ozone concentration, 8 seconds is enough to let all ozone absorbed in blood. \n \nDiscussion and Conclusions. \nThe experiment shows how quick ozone reacts with blood and claims for a trial with real SIEVO devices to achieve a real timing.","PeriodicalId":137241,"journal":{"name":"Journal of Ozone Therapy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ozone Therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7203/JO3T.2.3.2018.9611","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Introduction. Reading reference ozone books from Dra. Menendez, Dra. Viebhan, Dra. Borrelli and Dr. Bocci, proper timing for mixing ozone in blood during autohemotherapy is not calculated in a scientific way, having only an estimation of it based on changes in the blood color, more related to oxygen absorption than on ozone itself. Material and methods. We decided to reproduce a reduced model of great autohemotherapy or recently renamed as systemic indirect endovenous ozonotherapy (SIEVO) by the World Federation of Ozone Therapy – WFOT, using syringes to simplify the experiment. Our model consisted of a 20 mL syringe filled with 10 mL of blood withdrawn from healthy volunteers and mixed it gently but in controlled way with 10 mL medical ozone at different concentrations; after 5 and 8 seconds, the remaining gas was analyzed by an spectrophotometer based ozone detector to check the amount of ozone. Data were analyzed using a linear regression model. Results. Results show that even for 60 mcgr/mL ozone concentration, 8 seconds is enough to let all ozone absorbed in blood. Discussion and Conclusions. The experiment shows how quick ozone reacts with blood and claims for a trial with real SIEVO devices to achieve a real timing.
系统间接静脉内臭氧治疗中血液中臭氧吸收的科学方法
介绍。阅读德拉的臭氧参考书。梅内德斯,半径标注。Viebhan半径标注。Borrelli和Bocci博士指出,在自体血液治疗过程中混合臭氧的适当时机并没有以科学的方式计算,只能根据血液颜色的变化来估计,而血液颜色的变化与氧气吸收的关系比臭氧本身更大。材料和方法。为了简化实验,我们决定使用注射器重现一个缩小的自体血液治疗模型,或者最近由世界臭氧治疗联合会(WFOT)重新命名为全身间接静脉内臭氧治疗(SIEVO)。我们的模型包括一个20毫升的注射器,装满从健康志愿者身上提取的10毫升血液,并将其与10毫升不同浓度的医用臭氧轻轻地混合,但以可控的方式混合;在5秒和8秒后,用分光光度计对剩余气体进行分析,以检查臭氧的量。数据分析采用线性回归模型。结果。结果表明,即使在60 mcgr/mL的臭氧浓度下,8秒就足以让血液中的臭氧全部被吸收。讨论和结论。该实验显示了臭氧与血液的反应速度,并要求使用真正的SIEVO设备进行试验,以实现实时计时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信