{"title":"Three-phase four-leg shunt active power filter to compensate harmonics and reactive power","authors":"I. I. Abdalla, K. S. R. Rao, N. Perumal","doi":"10.1109/ISCI.2011.5958965","DOIUrl":null,"url":null,"abstract":"This paper presents a compensating system for the harmonics and the reactive power using four-leg shunt active power filter (SAPF) in a three-phase four-wire distribution network and aims to minimize the harmonics and neutral current. Two control approaches p-q theory based hysteresis current control and load current detection based hysteresis current control are proposed. To validate the compensation performance of SAPF a distribution network with nonlinear loads is simulated using MATLAB/Simulink software. Simulation results are presented to assess the performance of SAPF to minimize the total harmonics distortion (THD) and neutral current, as well as to compensate the reactive power.","PeriodicalId":166647,"journal":{"name":"2011 IEEE Symposium on Computers & Informatics","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 IEEE Symposium on Computers & Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISCI.2011.5958965","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

This paper presents a compensating system for the harmonics and the reactive power using four-leg shunt active power filter (SAPF) in a three-phase four-wire distribution network and aims to minimize the harmonics and neutral current. Two control approaches p-q theory based hysteresis current control and load current detection based hysteresis current control are proposed. To validate the compensation performance of SAPF a distribution network with nonlinear loads is simulated using MATLAB/Simulink software. Simulation results are presented to assess the performance of SAPF to minimize the total harmonics distortion (THD) and neutral current, as well as to compensate the reactive power.
三相四脚并联有源电力滤波器补偿谐波和无功功率
本文提出了一种采用四支路并联有源滤波器(SAPF)的三相四线制配电网谐波和无功补偿系统,以达到谐波和中性电流最小化的目的。提出了基于p-q理论的磁滞电流控制和基于负载电流检测的磁滞电流控制两种控制方法。为了验证SAPF的补偿性能,利用MATLAB/Simulink软件对一个具有非线性负荷的配电网进行了仿真。仿真结果验证了该滤波器在减小总谐波失真(THD)和中性电流以及补偿无功功率方面的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信