Frequency Response Analysis to recognize inductance variation in transformer due to internal short circuit

M. Bagheri, M. Naderi, T. Blackburn, Bao Toan Phung, Zhenyu Liu
{"title":"Frequency Response Analysis to recognize inductance variation in transformer due to internal short circuit","authors":"M. Bagheri, M. Naderi, T. Blackburn, Bao Toan Phung, Zhenyu Liu","doi":"10.1109/ASSCC.2012.6523350","DOIUrl":null,"url":null,"abstract":"Transformer diagnosis methods have been introduced and employed to recognize transformer internal defects since many years ago. In terms of mechanical defects in transformers, turn to turn and disc to disc short circuits in transformer windings are considered as one of the main problems in transformer active part. On the other hand, Frequency Response Analysis (FRA) is considered as a robust, sensitive and high accurate method to identify transformer mechanical defects. This study has concentrated on self-inductance variation recognition due to an internal short circuit in transformer using FRA signature. A single phase 11/0.25 kV, 25 kVA transformer has been taken as test object. Frequency response of the test object was recorded for open circuit and short circuit situations. Frequency response alteration in low frequencies caused by short circuit is interpreted through mathematical calculations. Frequency response trace deviation is employed to recognize self-inductance changes due to the internal short circuit.","PeriodicalId":341348,"journal":{"name":"2012 10th International Power & Energy Conference (IPEC)","volume":"74 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 10th International Power & Energy Conference (IPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2012.6523350","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

Abstract

Transformer diagnosis methods have been introduced and employed to recognize transformer internal defects since many years ago. In terms of mechanical defects in transformers, turn to turn and disc to disc short circuits in transformer windings are considered as one of the main problems in transformer active part. On the other hand, Frequency Response Analysis (FRA) is considered as a robust, sensitive and high accurate method to identify transformer mechanical defects. This study has concentrated on self-inductance variation recognition due to an internal short circuit in transformer using FRA signature. A single phase 11/0.25 kV, 25 kVA transformer has been taken as test object. Frequency response of the test object was recorded for open circuit and short circuit situations. Frequency response alteration in low frequencies caused by short circuit is interpreted through mathematical calculations. Frequency response trace deviation is employed to recognize self-inductance changes due to the internal short circuit.
频率响应分析识别变压器内部短路引起的电感变化
变压器诊断方法的引入和应用已经有很多年的历史了。在变压器的机械缺陷方面,变压器绕组的匝间短路和盘间短路被认为是变压器有源部件的主要问题之一。另一方面,频响分析(FRA)被认为是一种鲁棒、灵敏、高精度的变压器机械缺陷识别方法。本文主要研究了利用FRA信号识别变压器内部短路引起的自感变化。以单相11/0.25 kV, 25kva变压器为试验对象。记录了开路和短路情况下测试对象的频率响应。通过数学计算解释了短路引起的低频频率响应变化。频率响应走线偏差用于识别由于内部短路引起的自感变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信