Analysis of VFTO across bushing in 765kV gas insulated substation using EMTP software

R. Rao, J. Amarnath
{"title":"Analysis of VFTO across bushing in 765kV gas insulated substation using EMTP software","authors":"R. Rao, J. Amarnath","doi":"10.1109/ISEG.2014.7005588","DOIUrl":null,"url":null,"abstract":"Due to the opening or closing of circuit breakers and disconnect switches in Gas Insulated Substations (GIS), Very Fast Transient Over-voltages (VFTO) are generated, which will bring an instantaneous change in voltage with a very short rise time and it is normally followed by oscillation having high frequencies. This paper describes the variations of VFTO magnitudes transformer bushing of a 765 kV GIS during different switching operations have been calculated and compared by using EMTP.","PeriodicalId":105826,"journal":{"name":"2014 International Conference on Smart Electric Grid (ISEG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Smart Electric Grid (ISEG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEG.2014.7005588","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Due to the opening or closing of circuit breakers and disconnect switches in Gas Insulated Substations (GIS), Very Fast Transient Over-voltages (VFTO) are generated, which will bring an instantaneous change in voltage with a very short rise time and it is normally followed by oscillation having high frequencies. This paper describes the variations of VFTO magnitudes transformer bushing of a 765 kV GIS during different switching operations have been calculated and compared by using EMTP.
利用EMTP软件对765kV气体绝缘变电所VFTO跨套管进行分析
在气体绝缘变电站(GIS)中,由于断路器和断开开关的打开或关闭,会产生非常快的瞬态过电压(VFTO),它会带来电压的瞬时变化,上升时间很短,通常伴随着高频振荡。本文用EMTP方法计算比较了765kv GIS变压器套管在不同开关操作过程中VFTO幅度的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信