{"title":"Mitigation of Harmonic for an Arc Welding Machine by using Shunt Active Filter","authors":"S. Dessouky, Y. Abdalla, K. Sayed, W. Hafez","doi":"10.36039/AA102015001","DOIUrl":null,"url":null,"abstract":"This paper introduces a design and simulation of an adaptive shunt active filter (SAF) for harmonic mitigation of an arc welding machine. This type of welding machines causes unacceptable current distortions in the utility electrical distribution system, especially when an adjacent manufacturing facility with extensive electronic controls exists. This work demonstrates effective use of active low-pass filter with the pulse width modulator PWM carrier strategy to control the current of active filter. The method is based on frequency domain. A model of a typical power system coupled with arc welding machine is presented. The active filter are implemented in power electronic simulation software, representative waveforms and spectral analysis is presented, simulation results show that the proposed active filter is very effective in harmonic elimination of an arc welding machine.","PeriodicalId":360729,"journal":{"name":"Automation and Autonomous System","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Automation and Autonomous System","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36039/AA102015001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper introduces a design and simulation of an adaptive shunt active filter (SAF) for harmonic mitigation of an arc welding machine. This type of welding machines causes unacceptable current distortions in the utility electrical distribution system, especially when an adjacent manufacturing facility with extensive electronic controls exists. This work demonstrates effective use of active low-pass filter with the pulse width modulator PWM carrier strategy to control the current of active filter. The method is based on frequency domain. A model of a typical power system coupled with arc welding machine is presented. The active filter are implemented in power electronic simulation software, representative waveforms and spectral analysis is presented, simulation results show that the proposed active filter is very effective in harmonic elimination of an arc welding machine.
并联有源滤波器对弧焊机谐波的抑制
介绍了一种用于弧焊机谐波抑制的自适应并联有源滤波器的设计与仿真。这种类型的焊机在公用事业配电系统中造成不可接受的电流扭曲,特别是当相邻的制造工厂存在大量电子控制时。本研究证明了利用脉宽调制器PWM载波策略有效地控制有源低通滤波器的电流。该方法是基于频域的。提出了一个典型的电力系统与弧焊机耦合的模型。在电力电子仿真软件中实现了有源滤波器,给出了代表性波形和频谱分析,仿真结果表明所提出的有源滤波器对弧焊机谐波消除非常有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信