Studi Kemampuan Penyerapan Panas pada Atap Rumah Seng Berwarna Terhadap Intensitas Matahari dalam Mengatasi Global Warming

N. Nazaruddin, Teuku Zulfadli, Andi Mulkan
{"title":"Studi Kemampuan Penyerapan Panas pada Atap Rumah Seng Berwarna Terhadap Intensitas Matahari dalam Mengatasi Global Warming","authors":"N. Nazaruddin, Teuku Zulfadli, Andi Mulkan","doi":"10.23887/ijnse.v4i3.30065","DOIUrl":null,"url":null,"abstract":"The environmental temperature has increased significantly reaching 33oC as felt by the community, one of which is in the Aceh region which triggers Global Warming. As a result of the increase in temperature in the Aceh area, many buildings and houses become uncomfortable especially during the daytime because most house with zinc roof. This will cause the temperature in the house and the air around it to increase. Therefore, it is necessary to do research on the study of heat absorption on colored zinc roofs. This research method is to calculate the heat absorption (sun intensity) in zinc that has been coated with several kinds of colors such as white, red, blue, yellow and black. The purpose of this study was to determine the color that has the least amount of heat absorption to the sun's intensity. The highest room temperature on zinc-coated black is 49.2° C and the lowest is in white.  40.9°C from the pen. In the environmental temperature observation, there is the highest temperature at 12.00.  Room temperature increased the highest temperature at 12.00 on black zinc.  The distribution of room temperature can be averaged with a yellow color of 46.0°C, a black color of 49.2°C, a blue of 45.5°C and a white zinc of 40.9 oC.  The heat absorbed in the room is 47.9 joules, so from the overall average of the test it can be described that the room temperature is 45.6 and the zinc temperature is 53.8oC from the highest temperature difference at 12.00 WIB, room temperature and 13.00 WIB the highest absorption occurs at zinc temperature.","PeriodicalId":181108,"journal":{"name":"International Journal of Natural Science and Engineering","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Natural Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23887/ijnse.v4i3.30065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The environmental temperature has increased significantly reaching 33oC as felt by the community, one of which is in the Aceh region which triggers Global Warming. As a result of the increase in temperature in the Aceh area, many buildings and houses become uncomfortable especially during the daytime because most house with zinc roof. This will cause the temperature in the house and the air around it to increase. Therefore, it is necessary to do research on the study of heat absorption on colored zinc roofs. This research method is to calculate the heat absorption (sun intensity) in zinc that has been coated with several kinds of colors such as white, red, blue, yellow and black. The purpose of this study was to determine the color that has the least amount of heat absorption to the sun's intensity. The highest room temperature on zinc-coated black is 49.2° C and the lowest is in white.  40.9°C from the pen. In the environmental temperature observation, there is the highest temperature at 12.00.  Room temperature increased the highest temperature at 12.00 on black zinc.  The distribution of room temperature can be averaged with a yellow color of 46.0°C, a black color of 49.2°C, a blue of 45.5°C and a white zinc of 40.9 oC.  The heat absorbed in the room is 47.9 joules, so from the overall average of the test it can be described that the room temperature is 45.6 and the zinc temperature is 53.8oC from the highest temperature difference at 12.00 WIB, room temperature and 13.00 WIB the highest absorption occurs at zinc temperature.
研究了太阳在全球变暖时对有色锌房屋屋顶的吸收能力
社区感受到的环境温度显著上升,达到33摄氏度,其中一个是在亚齐地区,这引发了全球变暖。由于亚齐地区气温的升高,许多建筑物和房屋变得不舒服,特别是在白天,因为大多数房屋都是锌屋顶。这将导致房屋内和周围空气的温度升高。因此,有必要对彩锌屋面的吸热特性进行研究。这种研究方法是计算锌在涂上白、红、蓝、黄、黑等几种颜色后的吸热(太阳强度)。这项研究的目的是确定对太阳强度吸热最少的颜色。镀锌黑色的最高室温为49.2℃,最低室温为白色。40.9°C从笔。在环境温度观测中,最高温度为12.00。室温升高后黑锌的最高温度为12.00℃。室温分布可平均为黄色46.0℃,黑色49.2℃,蓝色45.5℃,白色锌40.9℃。房间吸收的热量为47.9焦耳,因此从测试的总体平均值可以看出,室温为45.6℃,锌温度为53.8℃,从12.00 WIB时的最高温差来看,室温和13.00 WIB时锌温度的吸收率最高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信