A new approach to on-line turn fault detection in AC motors

G. Kliman, W. Premerlani, R. A. Koegl, David Jeremiah Hoeweler
{"title":"A new approach to on-line turn fault detection in AC motors","authors":"G. Kliman, W. Premerlani, R. A. Koegl, David Jeremiah Hoeweler","doi":"10.1109/IAS.1996.557113","DOIUrl":null,"url":null,"abstract":"Turn fault detection is based on the principal that symmetrical (unfaulted) motors powered by symmetrical multiphase voltage sources will have no negative sequence currents flowing in the leads. A turn-to-turn fault will break that symmetry and give rise to a negative sequence current which may then be used as a measure of fault severity or to initiate protective action such as a circuit breaker trip. A new way of looking at the effects of turn faults has been developed that improves sensitivity and speed while reducing the probability of misdetection, taking into account voltage balance, load or voltage variation and instrument errors. The method has been implemented on a PC and tested, in real time, on a specially prepared small motor. Reliable detection of one shorted turn out of 648 turns per phase (in a Y connected motor) was demonstrated with the fault indicator becoming fully developed in two cycles of line frequency after initiation of the fault.","PeriodicalId":177291,"journal":{"name":"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"301","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.1996.557113","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 301

Abstract

Turn fault detection is based on the principal that symmetrical (unfaulted) motors powered by symmetrical multiphase voltage sources will have no negative sequence currents flowing in the leads. A turn-to-turn fault will break that symmetry and give rise to a negative sequence current which may then be used as a measure of fault severity or to initiate protective action such as a circuit breaker trip. A new way of looking at the effects of turn faults has been developed that improves sensitivity and speed while reducing the probability of misdetection, taking into account voltage balance, load or voltage variation and instrument errors. The method has been implemented on a PC and tested, in real time, on a specially prepared small motor. Reliable detection of one shorted turn out of 648 turns per phase (in a Y connected motor) was demonstrated with the fault indicator becoming fully developed in two cycles of line frequency after initiation of the fault.
交流电动机匝故障在线检测新方法
转动故障检测是基于对称多相电压源驱动的对称(无故障)电动机在引线中没有负序电流的原理。匝间故障将打破这种对称性,并产生负序电流,该电流可用作故障严重程度的测量或启动保护动作,如断路器跳闸。考虑到电压平衡、负载或电压变化和仪器误差,一种新的观察转向故障影响的方法已经被开发出来,它提高了灵敏度和速度,同时减少了误检的可能性。该方法已在PC机上实现,并在特制的小型电机上进行了实时测试。可靠地检测出每相648转中的一个短转(在Y连接电机中),故障指示器在故障启动后的两个线路频率周期内完全发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信