Assessment of scatter components in multispectral PET imaging

M. Bentourkia, P. Msaki, J. Cadorette, R. Lecomte
{"title":"Assessment of scatter components in multispectral PET imaging","authors":"M. Bentourkia, P. Msaki, J. Cadorette, R. Lecomte","doi":"10.1109/NSSMIC.1993.373541","DOIUrl":null,"url":null,"abstract":"High resolution images in PET based on small individual detectors are obtained at the cost of poor sensitivity and significant scatter in the detectors. These drawbacks can be partially overcome by acquiring low-energy events and by using more efficient energy-dependent scatter correction methods. The feasibility of multispectral scatter correction was assessed by analyzing projection response functions measured in several energy windows to extract scatter components. While the fraction of well-positioned events drops from 90% in the photopeak region to less than 20% in the lower windows, the detector scatter fraction increases from 5% to 60% in the same range. By independent restoration of the latter component in every energy window, nearly 90% of all detected events can be recovered. Multispectral acquisition, therefore, is a promising approach for recovering sensitivity without loss of resolution in high resolution PET.<<ETX>>","PeriodicalId":287813,"journal":{"name":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","volume":"55 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1993.373541","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

High resolution images in PET based on small individual detectors are obtained at the cost of poor sensitivity and significant scatter in the detectors. These drawbacks can be partially overcome by acquiring low-energy events and by using more efficient energy-dependent scatter correction methods. The feasibility of multispectral scatter correction was assessed by analyzing projection response functions measured in several energy windows to extract scatter components. While the fraction of well-positioned events drops from 90% in the photopeak region to less than 20% in the lower windows, the detector scatter fraction increases from 5% to 60% in the same range. By independent restoration of the latter component in every energy window, nearly 90% of all detected events can be recovered. Multispectral acquisition, therefore, is a promising approach for recovering sensitivity without loss of resolution in high resolution PET.<>
多光谱PET成像中散射分量的评估
基于小型单个探测器的PET高分辨率图像的代价是探测器的灵敏度较低和散射明显。这些缺点可以通过获取低能量事件和使用更有效的能量相关散射校正方法来部分克服。通过分析在多个能量窗测量的投影响应函数来提取散射分量,评估了多光谱散射校正的可行性。当定位良好的事件的比例从光峰区域的90%下降到较低窗口的不到20%时,探测器的散射分数在相同范围内从5%增加到60%。通过对每个能量窗口的后一分量的独立恢复,可以恢复近90%的检测到的事件。因此,多光谱采集是在不损失分辨率的情况下恢复高分辨率PET灵敏度的一种很有前途的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信