Electrical bearing damage — A lurking problem in inverter-driven traction motors

A. Willwerth, M. Roman
{"title":"Electrical bearing damage — A lurking problem in inverter-driven traction motors","authors":"A. Willwerth, M. Roman","doi":"10.1109/ITEC.2013.6573484","DOIUrl":null,"url":null,"abstract":"With the increasing use of inverter-controlled traction motor systems in electric rail, road, and off-road vehicles, protecting motor bearings will become a key requirement for reliability. Partial mitigation measures against inverter-induced electrical bearing damage can merely shift the damage to gearbox bearings and create more maintenance headaches. In some vehicles, stray currents can also cause electromagnetic interference (EMI) and/or radio frequency interference (RFI) that can jeopardize electronic control systems. The best long-term solution is a contact/noncontact motor shaft grounding ring that works in the unique electric vehicle environment of high revolutions per minute (r/min), rapid acceleration, etc.","PeriodicalId":118616,"journal":{"name":"2013 IEEE Transportation Electrification Conference and Expo (ITEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"26","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE Transportation Electrification Conference and Expo (ITEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITEC.2013.6573484","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 26

Abstract

With the increasing use of inverter-controlled traction motor systems in electric rail, road, and off-road vehicles, protecting motor bearings will become a key requirement for reliability. Partial mitigation measures against inverter-induced electrical bearing damage can merely shift the damage to gearbox bearings and create more maintenance headaches. In some vehicles, stray currents can also cause electromagnetic interference (EMI) and/or radio frequency interference (RFI) that can jeopardize electronic control systems. The best long-term solution is a contact/noncontact motor shaft grounding ring that works in the unique electric vehicle environment of high revolutions per minute (r/min), rapid acceleration, etc.
电气轴承损坏——变频器驱动牵引电动机的一个潜在问题
随着变频控制牵引电机系统在铁路、公路和越野车辆中的应用越来越多,保护电机轴承将成为可靠性的关键要求。针对逆变器引起的电气轴承损坏的部分缓解措施只能将损坏转移到齿轮箱轴承上,并造成更多的维护问题。在某些车辆中,杂散电流还会引起电磁干扰(EMI)和/或射频干扰(RFI),从而危及电子控制系统。最佳的长期解决方案是接触式/非接触式电机轴接地环,该接地环可在每分钟高转数(r/min),快速加速等独特的电动汽车环境中工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信