Influence of parameter uncertainties on the performance of some induction actuator indirect field oriented control schemes

B. Robyns, H. Buyse, F. Labrique
{"title":"Influence of parameter uncertainties on the performance of some induction actuator indirect field oriented control schemes","authors":"B. Robyns, H. Buyse, F. Labrique","doi":"10.1109/ISIE.1993.268811","DOIUrl":null,"url":null,"abstract":"The aim of this paper is to compare the performance of two indirect field oriented control schemes. In the first one, the Park components of the stator currents are controlled by two PI regulators, and in the second one, these currents are not directly controlled and there is no current measurement. It is shown that the sensitivity of the flux control to parameter uncertainties is generally smaller in the control scheme without current controllers than in the control scheme with current PI controllers, in spite of the fact the latter offers a more precise current control. It is also shown that the control scheme without current measurement allows to develop a fully digital implementation on low cost microprocessors. Experiments on a laboratory prototype confirm the good performance of this simplified control scheme.<<ETX>>","PeriodicalId":267349,"journal":{"name":"ISIE '93 - Budapest: IEEE International Symposium on Industrial Electronics Conference Proceedings","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISIE '93 - Budapest: IEEE International Symposium on Industrial Electronics Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.1993.268811","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The aim of this paper is to compare the performance of two indirect field oriented control schemes. In the first one, the Park components of the stator currents are controlled by two PI regulators, and in the second one, these currents are not directly controlled and there is no current measurement. It is shown that the sensitivity of the flux control to parameter uncertainties is generally smaller in the control scheme without current controllers than in the control scheme with current PI controllers, in spite of the fact the latter offers a more precise current control. It is also shown that the control scheme without current measurement allows to develop a fully digital implementation on low cost microprocessors. Experiments on a laboratory prototype confirm the good performance of this simplified control scheme.<>
参数不确定性对异步作动器间接磁场定向控制方案性能的影响
本文的目的是比较两种间接场定向控制方案的性能。在第一个电路中,定子电流的Park分量由两个PI调节器控制,而在第二个电路中,这些电流不是直接控制的,没有电流测量。结果表明,在无电流控制器的控制方案中,磁链控制对参数不确定性的灵敏度通常小于有电流PI控制器的控制方案,尽管后者提供了更精确的电流控制。结果还表明,不需要电流测量的控制方案可以在低成本微处理器上开发完全数字化的实现。在实验室样机上的实验验证了该简化控制方案的良好性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信