Continuous pH and HCO3 monitoring during hemodiafiltration without blood sampling.

ASAIO transactions Pub Date : 1991-10-01
P M Ghezzi, R Gervasio, J Botella
{"title":"Continuous pH and HCO3 monitoring during hemodiafiltration without blood sampling.","authors":"P M Ghezzi,&nbsp;R Gervasio,&nbsp;J Botella","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The correction of acid-base balance during hemodialysis, especially in high-efficiency techniques, could present some problem related to the lack of an adequate monitoring of pH and blood gases. During hemodiafiltration (HDF), performed with the two-chamber technique (paired filtration dialysis, PFD), the ultrafiltrate (Uf) is continuously available, unmixed with the dialysate. Connecting a pH electrode (as Ag/C1Ag) to the Uf circuit, the authors made 40 determinations on 16 different PFD patients, and they correlated the Uf values obtained with those measured on arterial blood with standard methods. The one sample analysis gave a t = 10.145 (p = 0.0), and the linear regression analysis an r = 0.931 (p = 0.0). At 30 min, in 8 PFD patients, the HCO3 values obtained from Uf, pH and transcutaneous PCO2, gave a t = 6.37 (p = 0.0004), and an r = 0.939 (p = 0.00052). In conclusion, during HDF performed with PFD, continuous pH monitoring of the patient is possible without blood sampling. Moreover, correlation with the transcutaneous PCO2 measurement could provide HCO3 values in real time.</p>","PeriodicalId":77493,"journal":{"name":"ASAIO transactions","volume":"37 4","pages":"605-7"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO transactions","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The correction of acid-base balance during hemodialysis, especially in high-efficiency techniques, could present some problem related to the lack of an adequate monitoring of pH and blood gases. During hemodiafiltration (HDF), performed with the two-chamber technique (paired filtration dialysis, PFD), the ultrafiltrate (Uf) is continuously available, unmixed with the dialysate. Connecting a pH electrode (as Ag/C1Ag) to the Uf circuit, the authors made 40 determinations on 16 different PFD patients, and they correlated the Uf values obtained with those measured on arterial blood with standard methods. The one sample analysis gave a t = 10.145 (p = 0.0), and the linear regression analysis an r = 0.931 (p = 0.0). At 30 min, in 8 PFD patients, the HCO3 values obtained from Uf, pH and transcutaneous PCO2, gave a t = 6.37 (p = 0.0004), and an r = 0.939 (p = 0.00052). In conclusion, during HDF performed with PFD, continuous pH monitoring of the patient is possible without blood sampling. Moreover, correlation with the transcutaneous PCO2 measurement could provide HCO3 values in real time.

血液滤过期间连续监测pH和HCO3而不采血。
血液透析过程中酸碱平衡的校正,特别是在高效技术中,可能会出现一些与缺乏足够的pH和血气监测相关的问题。在使用双室技术(配对过滤透析,PFD)进行血液滤过(HDF)期间,超滤液(Uf)持续可用,未与透析液混合。将pH电极(如Ag/C1Ag)连接到Uf电路上,作者对16名不同的PFD患者进行了40次测定,并将所得的Uf值与标准方法测得的动脉血Uf值相关联。单样本分析得出t = 10.145 (p = 0.0),线性回归分析得出r = 0.931 (p = 0.0)。在8例PFD患者中,30分钟时,通过Uf、pH和经皮PCO2获得的HCO3值t = 6.37 (p = 0.0004), r = 0.939 (p = 0.00052)。总之,在与PFD一起进行HDF期间,可以在不采血的情况下对患者进行连续的pH监测。此外,与经皮PCO2测量的相关性可以实时提供HCO3值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信