Combination of Existing Transformer and Newly Placed Transformer for Optimal Electric Power Distribution System

H. Saragi, Iswanti Sihaloho, W. Siagian, R. Pardede, Santi Agustina Manalu
{"title":"Combination of Existing Transformer and Newly Placed Transformer for Optimal Electric Power Distribution System","authors":"H. Saragi, Iswanti Sihaloho, W. Siagian, R. Pardede, Santi Agustina Manalu","doi":"10.1109/ISMODE56940.2022.10181002","DOIUrl":null,"url":null,"abstract":"Electric power is one of the basic human needs. To fulfil the consumer’s power requirement, the electricity supplier and provider need an economical and reliable distribution system. Nowadays, a transformer has been installed in the power distribution system, and if it is moved, it will need a high replacement cost. Therefore, the development of the power distribution system will not change the existing transformer location. However, the current transformer capacity does not adequate to provide the electricity requirement; therefore, newly placed transformers are required to support and provide the needs. This research aims to determine the optimal combination of existing and newly placed transformers to provide a reliable and economical power system. The reliable power distribution system is gained from the shortest power connection distance and low power loss distribution system. The most economical power system is gained by finding the transformation location that produces the lowest cost for power distribution installation, system installation, and lowest transformer losses. The optimal condition is calculated by a genetic algorithm respecting the voltage limit regulation. The result combines existing transformers and newly placed transformers in PT. PLN (PERSERO) Rayon Dolok Masihul Sumatera Utara is the transformer coordinate and capacity, the transformer load combination, and the minimum investment cost.","PeriodicalId":335247,"journal":{"name":"2022 2nd International Seminar on Machine Learning, Optimization, and Data Science (ISMODE)","volume":"108 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 2nd International Seminar on Machine Learning, Optimization, and Data Science (ISMODE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISMODE56940.2022.10181002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electric power is one of the basic human needs. To fulfil the consumer’s power requirement, the electricity supplier and provider need an economical and reliable distribution system. Nowadays, a transformer has been installed in the power distribution system, and if it is moved, it will need a high replacement cost. Therefore, the development of the power distribution system will not change the existing transformer location. However, the current transformer capacity does not adequate to provide the electricity requirement; therefore, newly placed transformers are required to support and provide the needs. This research aims to determine the optimal combination of existing and newly placed transformers to provide a reliable and economical power system. The reliable power distribution system is gained from the shortest power connection distance and low power loss distribution system. The most economical power system is gained by finding the transformation location that produces the lowest cost for power distribution installation, system installation, and lowest transformer losses. The optimal condition is calculated by a genetic algorithm respecting the voltage limit regulation. The result combines existing transformers and newly placed transformers in PT. PLN (PERSERO) Rayon Dolok Masihul Sumatera Utara is the transformer coordinate and capacity, the transformer load combination, and the minimum investment cost.
配电系统优化中既有变压器与新变压器的组合
电力是人类的基本需求之一。为了满足用户的用电需求,电力供应商和供应商需要一个经济可靠的配电系统。如今,配电系统中已经安装了变压器,如果将其移动,则需要很高的更换成本。因此,配电系统的发展不会改变现有变压器的位置。但是,当前变压器的容量不足以提供用电需求;因此,新放置的变压器需要支持和提供需求。本研究旨在确定现有变压器和新变压器的最佳组合,以提供可靠和经济的电力系统。可靠的配电系统是指接线距离短、损耗小的配电系统。寻找配电安装成本、系统安装成本和变压器损耗最低的变电站位置,从而获得最经济的电力系统。采用遗传算法计算了电压极限调节的最优条件。结合PT. PLN (PERSERO) Rayon Dolok Masihul sumata Utara现有变压器和新放置变压器的结果是变压器坐标和容量,变压器负载组合,以及最小投资成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信