Effect of Height Differences on the Retention and Wear Behaviour of Ball Attachment System Over Mandibular Dual Implants

J. Vidhya
{"title":"Effect of Height Differences on the Retention and Wear Behaviour of Ball Attachment System Over Mandibular Dual Implants","authors":"J. Vidhya","doi":"10.33552/OJDOH.2021.04.000581","DOIUrl":null,"url":null,"abstract":"Purpose of the study: To comparatively evaluate the effect of height differences on the retention and wear behaviour of ball attachment system over mandibular dual implants. Materials and methods: Two groups of twenty samples each containing polymerised master block of dual implant analogues at same height in Group 1 and dual implant analogues of different heights in Group 2 were fabricated along with ball abutments, nylon cap and metal housing. Qualitative analysis of samples for wear factor were carried out using stereomicroscope and quantitative analysis of retention force at baseline, 360, 720, 1080, 1440 insertion-removal cycles were determined using Universal testing machine. statistical analysis were carried out using independent ‘t’ test and paired sample ‘t’ test. Results: Group I test samples, the sample mean obtained at baseline, 360, 720,1080, and 1440 cycles were 24.73N, 23.49N, 22.46N, 21.07N, & 19.28N respectively. Group II test samples, the sample mean obtained at baseline, 360, 720,1080 & 1440 cycles were 27.13N 25.80N, 24.16N, 22.73N and 21.85N respectively. comparison of the mean retention force of the test samples at baseline, 360 (3 months), 720 (6 months), 1080 (9 months) and after 1440 (12months) insertion-removal cycles within Group 1 and Group II using Paired sample ‘t’-test was statistically significant at all levels. Conclusion: Retention force was found to be higher on dual implants placed at different heights in mandibular anterior region and is statistically significant and corroborated by the Lesser surface deformations of attachment system.","PeriodicalId":361768,"journal":{"name":"Online Journal of Dentistry & Oral Health","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Online Journal of Dentistry & Oral Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33552/OJDOH.2021.04.000581","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose of the study: To comparatively evaluate the effect of height differences on the retention and wear behaviour of ball attachment system over mandibular dual implants. Materials and methods: Two groups of twenty samples each containing polymerised master block of dual implant analogues at same height in Group 1 and dual implant analogues of different heights in Group 2 were fabricated along with ball abutments, nylon cap and metal housing. Qualitative analysis of samples for wear factor were carried out using stereomicroscope and quantitative analysis of retention force at baseline, 360, 720, 1080, 1440 insertion-removal cycles were determined using Universal testing machine. statistical analysis were carried out using independent ‘t’ test and paired sample ‘t’ test. Results: Group I test samples, the sample mean obtained at baseline, 360, 720,1080, and 1440 cycles were 24.73N, 23.49N, 22.46N, 21.07N, & 19.28N respectively. Group II test samples, the sample mean obtained at baseline, 360, 720,1080 & 1440 cycles were 27.13N 25.80N, 24.16N, 22.73N and 21.85N respectively. comparison of the mean retention force of the test samples at baseline, 360 (3 months), 720 (6 months), 1080 (9 months) and after 1440 (12months) insertion-removal cycles within Group 1 and Group II using Paired sample ‘t’-test was statistically significant at all levels. Conclusion: Retention force was found to be higher on dual implants placed at different heights in mandibular anterior region and is statistically significant and corroborated by the Lesser surface deformations of attachment system.
高度差异对下颌双种植体球附着系统固位和磨损行为的影响
目的:比较评价高度差异对下颌双种植体球附着系统固位和磨损行为的影响。材料和方法:制作两组样品,每组20个,每组含有相同高度的双种植类似物聚合母块,第1组含有不同高度的双种植类似物,第2组含有球基台、尼龙帽和金属外壳。采用体视显微镜对试样的磨损系数进行定性分析,并对试样在基线、360、720、1080、1440次插拔循环时的固位力进行定量分析。采用独立t检验和配对样本t检验进行统计分析。结果:第一组测试样本,基线、360、720、1080、1440个循环时获得的样本均值分别为24.73N、23.49N、22.46N、21.07N、19.28N。II组试验样本,基线、360、720、1080和1440个周期的样本均值分别为27.13N、25.80N、24.16N、22.73N和21.85N。配对样本“t”检验比较1组和II组在基线、360(3个月)、720(6个月)、1080(9个月)和1440(12个月)插拔周期后测试样本的平均滞留力,各水平均有统计学意义。结论:下颌前区放置不同高度的双种植体固位力更高,具有统计学意义,附着系统表面变形较小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信