Effects of impression material and implant angulation on the impression accuracy of external connection implants: An in vitro study

Dani Irani, Mayssaê El Ahmadié
{"title":"Effects of impression material and implant angulation on the impression accuracy of external connection implants: An in vitro study","authors":"Dani Irani, Mayssaê El Ahmadié","doi":"10.12816/0055825","DOIUrl":null,"url":null,"abstract":"A precise impression is mandatory to obtain passive fit in implant-supported prostheses. The aim of this study was to evaluate the effect of impression material and implant angulation on the impression accuracy of external-connection implants. Four customized epoxy resin master models, with twoimplant analogs placed parallel or with different degrees of divergence (10, 20 and 30 degrees), were fabricated with their corresponding passively fitted reference frameworks. Ten impressions were taken, for each model, with vinyl polysiloxane (VPS) and polyether (PE) using custom open tray impression technique. Impressions were poured with type IV dental stone and vertical discrepancies between the reference frameworks and the platforms of the implant replicas were evaluated, with a stereo video microscope, applying the one-screw test. The data were analyzed using two-way ANOVA, Sidak, and one-sample t-test at p ≤ 0.05. No significant differences were found between PE and VPS at various angulations (p > 0.05). However, all groups showed a significant difference (p 0.05). Cependant, les groupes ont montre une difference significative en comparaison avec la valeur reelle (p < 0.05). Tout en considerant les limitations de l’etude, le produit d’empreinte et l’angulation de l’implant n’ont pas d’effet sur la precision de l’empreinte en cas d’implants a connexions externes.","PeriodicalId":322244,"journal":{"name":"International Arab Journal of Dentistry","volume":"11 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Arab Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12816/0055825","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A precise impression is mandatory to obtain passive fit in implant-supported prostheses. The aim of this study was to evaluate the effect of impression material and implant angulation on the impression accuracy of external-connection implants. Four customized epoxy resin master models, with twoimplant analogs placed parallel or with different degrees of divergence (10, 20 and 30 degrees), were fabricated with their corresponding passively fitted reference frameworks. Ten impressions were taken, for each model, with vinyl polysiloxane (VPS) and polyether (PE) using custom open tray impression technique. Impressions were poured with type IV dental stone and vertical discrepancies between the reference frameworks and the platforms of the implant replicas were evaluated, with a stereo video microscope, applying the one-screw test. The data were analyzed using two-way ANOVA, Sidak, and one-sample t-test at p ≤ 0.05. No significant differences were found between PE and VPS at various angulations (p > 0.05). However, all groups showed a significant difference (p 0.05). Cependant, les groupes ont montre une difference significative en comparaison avec la valeur reelle (p < 0.05). Tout en considerant les limitations de l’etude, le produit d’empreinte et l’angulation de l’implant n’ont pas d’effet sur la precision de l’empreinte en cas d’implants a connexions externes.
印模材料和种植体角度对外连接种植体印模精度影响的体外研究
在种植体支持的假体中,精确的印模是获得被动配合的必要条件。本研究的目的是评估印模材料和种植体角度对外连接种植体印模精度的影响。四个定制的环氧树脂主模型,两个种植体类似物平行放置或不同程度的发散(10度,20度和30度),与相应的被动拟合参考框架一起制作。每个模型用乙烯基聚硅氧烷(VPS)和聚醚(PE)使用定制的开盘印模技术进行10次印模。用IV型牙石浇铸印模,用立体视频显微镜评估参考框架和平台之间的垂直差异,采用单螺钉测试。数据分析采用双因素方差分析、Sidak和单样本t检验,p≤0.05。不同角度PE和VPS无显著差异(p > 0.05)。各组间比较差异有统计学意义(p < 0.05)。此外,两组间的差异均无统计学意义(p < 0.05)。考虑到对结构的限制,产品的设计,角度的设计,插入的设计,效果的设计,精度的设计,插入的设计,连接的外部。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书