Maya Prananda Sari, Gabriela Evania Sulisityo, M. Pujiantara, M. Purnomo
{"title":"Chaotic Firefly with Tent Map Algorithm for Overcurrent Relay in MeshedDistribution System","authors":"Maya Prananda Sari, Gabriela Evania Sulisityo, M. Pujiantara, M. Purnomo","doi":"10.1109/ICITEED.2018.8534779","DOIUrl":null,"url":null,"abstract":"Development of electrical power system is linear with the increasing number of Distribution Generation (DG), which is change the pattern of power system protection due to the power flow and short circuit, especially in meshed distribution system. The analysis of short circuit is needed to obtain a reliable power system protection. This paper proposed Chaotic Firefly with tent map algorithm (CFA) method to get the minimum overcurrent relays time operation using the inverse time current characteristic. The proposed method had been compared with Firefly Algorithm (FA) in IEEE -9 bus with two DG. The result of total relay time operation using Chaotic Firefly with tent map algorithm is 3.557 seconds which is faster than another method.","PeriodicalId":142523,"journal":{"name":"2018 10th International Conference on Information Technology and Electrical Engineering (ICITEE)","volume":"31 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 10th International Conference on Information Technology and Electrical Engineering (ICITEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICITEED.2018.8534779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Development of electrical power system is linear with the increasing number of Distribution Generation (DG), which is change the pattern of power system protection due to the power flow and short circuit, especially in meshed distribution system. The analysis of short circuit is needed to obtain a reliable power system protection. This paper proposed Chaotic Firefly with tent map algorithm (CFA) method to get the minimum overcurrent relays time operation using the inverse time current characteristic. The proposed method had been compared with Firefly Algorithm (FA) in IEEE -9 bus with two DG. The result of total relay time operation using Chaotic Firefly with tent map algorithm is 3.557 seconds which is faster than another method.